40HP Carlyle Carrier Carrier kompresory 06EA299600 pre klimatizáciu
CARLYLE KOMPRESOR D séria
Carlyle | Služba Carlyle | tepl. | Motor | CFM | CFH | Nie | Nie | Potenciál | Olej | Nízka teplota | Med Temp. | |
OEM model | Výmena | Rozsah | Veľkosť | of | of | Vykladanie | Nabite | EER | EER | |||
číslo | Model | R404a | HP | Cyl | hlavy | Etapy | Pinty | R404a @ | R404a @ | |||
-0,003846154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 až 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 ku 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 ku 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 až 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 až 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 až 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 ku 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 až 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 až 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 až 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 až 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 až 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 až 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 až 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 až 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 až 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 až 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376… | 0 až 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 až 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
KOMPRESOR CARLYLE Séria ES
Carlyle | Služba Carlyle | tepl. | Motor | CFM | CFH | Nie | Nie | Potenciál | Olej | Nízka teplota | Med Temp. | |
OEM model | Výmena | Rozsah | Veľkosť | of | of | Vykladanie | Nabite | EER | EER | |||
číslo | Model | R404a | HP | Cyl | hlavy | Etapy | Pinty | R404a @ | R404a @ | |||
-0,003846154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 až 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 ku 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 ku 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 až 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 až 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 až 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 ku 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 až 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 až 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 až 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 až 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 až 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 až 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 až 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 až 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 až 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 až 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376… | 0 až 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 až 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
Popis
Polohermetické kompresory Carlyle 06D/E sú ideálne pre komerčné chladenie, klimatizáciu, procesné chladenie a environmentálne komory.Sú mimoriadne flexibilné a možno ich použiť s mnohými novými chladivami HFC, ako sú R-507, R-404A, R-407C a R-134a, okrem bežných chladív (R-12, R-22 a R -502).Kompresory môžu byť prevádzkované pri 50 alebo 60 hertzoch.Mnohé z významných vlastností kompresorov 06D/E sú uvedené nižšie.
Vlastnosti:
– Vysokoprietokové, automaticky reverzibilné olejové čerpadlo poskytuje objemové mazanie olejom.
– Systém odvetrávania kľukovej skrine vyrovnáva tlak počas štartovania a zabezpečuje návrat oleja do vane.
– Nadrozmerná vaňa obsahuje dodatočný olej v kľukovej skrini, aby sa zabránilo poklesu hladiny pod bezpečný rozsah mazania počas zaplavených štartov.
– Tvarované piesty znižujú vôle valcov, aby sa zvýšila kapacita a účinnosť kompresora.
– Vysokoúčinné ventily poskytujú zvýšený prietok chladiva a nižšie tlakové straty.
– Elektronický spínač tlaku oleja.