40HP Carlyle kandekompressorid 06EA299600 kliimaseadme jaoks
CARLYLE D-seeria KOMPRESSOR
Carlyle | Carlyle'i teenus | Temp. | Mootor | CFM | CFH | Ei. | Ei. | potentsiaal | Õli | Madal Temp. | Keskmine Temp. | |
OEM mudel | Asendamine | Vahemik | Suurus | of | of | Mahalaadimine | Lae | EER | EER | |||
Number | Mudel | R404a | HP | Cyl | Pead | Etapid | Pints | R404a @ | R404a @ | |||
-0,003846154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 kuni 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 kuni 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 kuni 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 kuni 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 kuni 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 kuni 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 kuni 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 kuni 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 kuni 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 kuni 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 kuni 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 kuni 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 kuni 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 kuni 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 kuni 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 kuni 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 kuni 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376… | 0 kuni 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 kuni 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
CARLYLE KOMPRESSOR ESari
Carlyle | Carlyle'i teenus | Temp. | Mootor | CFM | CFH | Ei. | Ei. | potentsiaal | Õli | Madal Temp. | Keskmine Temp. | |
OEM mudel | Asendamine | Vahemik | Suurus | of | of | Mahalaadimine | Lae | EER | EER | |||
Number | Mudel | R404a | HP | Cyl | Pead | Etapid | Pints | R404a @ | R404a @ | |||
-0,003846154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 kuni 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 kuni 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 kuni 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 kuni 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 kuni 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 kuni 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 kuni 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 kuni 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 kuni 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 kuni 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 kuni 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 kuni 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 kuni 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 kuni 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 kuni 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 kuni 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 kuni 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376… | 0 kuni 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 kuni 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
Kirjeldus
Carlyle 06D/E poolhermeetilised kompressorid sobivad ideaalselt kaubanduslikuks külmutus-, kliima-, protsessijahutus- ja keskkonnakambriteks.Need on äärmiselt paindlikud ja neid saab lisaks tavalistele külmutusagensidele (R-12, R-22 ja R) kasutada ka paljude uute HFC-külmaainetega, nagu R-507, R-404A, R-407C ja R-134a. -502).Kompressorid võivad töötada sagedusel 50 või 60 hertsi.Paljud 06D/E kompressorite silmapaistvad omadused on loetletud allpool.
Funktsioonid:
– Suure vooluhulgaga, automaatselt pööratav õlipump tagab mahuga õlimäärimise.
– Karteri õhutussüsteem ühtlustab käivitamise ajal survet ja tagab õli tagasivoolu karterisse.
– Liiga suur kogus mahutab karteris lisaõli, et vältida üleujutatud käivitumisel taseme langemist allapoole ohutut määrimisvahemikku.
– Kontuuriga kolvid vähendavad silindrite vahekaugust, et suurendada kompressori võimsust ja tõhusust.
– Suure efektiivsusega ventiilid tagavad suurema jahutusaine voolu ja väiksema rõhulanguse.
– Elektrooniline õlirõhu lüliti.