40HP Carlyle Carrier Compressors 06EA299600 para sa Air Conditioning

Maikling Paglalarawan:

Brand : Tagadala
Modelo : 06EA299600
Kapangyarihan: 40 hp
Silindro: 6
Kapasidad (m3/h): 140.40 m3/h
Singil ng langis: 9 L
Net Timbang : 236 kg
Nagpapalamig : R22


Detalye ng Produkto

Mga Tag ng Produkto

CARLYLE COMPRESSOR D Series

Carlyle Serbisyo ni Carlyle Temp. Motor CFM CFH Hindi. Hindi. Potensyal Langis Mababang Temp. Med Temp.
Modelo ng OEM Pagpapalit Saklaw Sukat of of Nagbabawas ng karga singilin EER EER
Numero Modelo R404a HP Si Cyl Mga ulo Mga yugto Pint R404a @ R404a @
-0.003846154 20/110/65
06DM8080… 06DM8086… 0 hanggang 50 3 8 480 2 1 0 3 8.4
06DR1090… 06DR1086… -40 hanggang 0 2 8.7 522 2 1 0 3 5.4
06DR0130… 06DR0136… -40 hanggang 0 3 13 786 4 2 1 4.5 5.3
06DM3130… 06DM3136… 0 hanggang 50 5 13 786 4 2 1 4.5 9.3
06DR3160… 06DR3166… -40 hanggang 25 5 15.9 954 4 2 1 4.5 5.4 9.3
06DM3160… 06DM3166… 0 hanggang 25 5 15.9 954 4 2 1 4.5 9
06DR7180… 06DR7186… -40 hanggang 0 5 18.3 1100 4 2 1 5.5 5.5
06DA8182… 06DS8186… 0 hanggang 50 6 1/2 18.3 1100 4 2 1 5.5 8.6
06DR8200… 06DR8206… -40 hanggang 40 6 1/2 20 1200 4 2 1 5.5 5.6 9.4
06DR7240… 06DR7246… -40 hanggang 25 6 1/2 23.9 1435 6 3 2 8 5.6 9.2
06DR7250… 06DR7256… -40 hanggang 25 6 1/2 23.9 1435 6 3 2 8 5.6 9.2
06DA8242… 06DS8246 0 hanggang 50 7 1/2 23.9 1435 6 3 2 8 8.6
06DA8252… 06DS8256… 0 hanggang 50 7 1/2 23.9 1435 6 3 2 8 8.6
06DR2280… 06DR2286… -40 hanggang 30 7 1/2 28 1680 6 3 2 8 5.7 9.2
06DA3282… 06DS3286… 0 hanggang 50 10 28 1680 6 3 2 8 8.6
06DR3370… 06DR3376… -40 hanggang 25 10 37.1 2225 6 3 2 8 5.7 9.2
06DM3370… 06DM3376… 0 hanggang 25 10 37.1 2225 6 3 2 8 8.7
06DA5372… 06DA5376… 0 hanggang 50 15 37.1 2225 6 3 2 8 8.7
06DR5410… 06DR5416… -40 hanggang 30 15 41 2460 6 3 2 8 5 9

CARLYLE COMPRESSOR ESeries

Carlyle Serbisyo ni Carlyle Temp. Motor CFM CFH Hindi. Hindi. Potensyal Langis Mababang Temp. Med Temp.
Modelo ng OEM Pagpapalit Saklaw Sukat of of Nagbabawas ng karga singilin EER EER
Numero Modelo R404a HP Si Cyl Mga ulo Mga yugto Pint R404a @ R404a @
-0.003846154 20/110/65
06DM8080… 06DM8086… 0 hanggang 50 3 8 480 2 1 0 3 8.4
06DR1090… 06DR1086… -40 hanggang 0 2 8.7 522 2 1 0 3 5.4
06DR0130… 06DR0136… -40 hanggang 0 3 13 786 4 2 1 4.5 5.3
06DM3130… 06DM3136… 0 hanggang 50 5 13 786 4 2 1 4.5 9.3
06DR3160… 06DR3166… -40 hanggang 25 5 15.9 954 4 2 1 4.5 5.4 9.3
06DM3160… 06DM3166… 0 hanggang 25 5 15.9 954 4 2 1 4.5 9
06DR7180… 06DR7186… -40 hanggang 0 5 18.3 1100 4 2 1 5.5 5.5
06DA8182… 06DS8186… 0 hanggang 50 6 1/2 18.3 1100 4 2 1 5.5 8.6
06DR8200… 06DR8206… -40 hanggang 40 6 1/2 20 1200 4 2 1 5.5 5.6 9.4
06DR7240… 06DR7246… -40 hanggang 25 6 1/2 23.9 1435 6 3 2 8 5.6 9.2
06DR7250… 06DR7256… -40 hanggang 25 6 1/2 23.9 1435 6 3 2 8 5.6 9.2
06DA8242… 06DS8246 0 hanggang 50 7 1/2 23.9 1435 6 3 2 8 8.6
06DA8252… 06DS8256… 0 hanggang 50 7 1/2 23.9 1435 6 3 2 8 8.6
06DR2280… 06DR2286… -40 hanggang 30 7 1/2 28 1680 6 3 2 8 5.7 9.2
06DA3282… 06DS3286… 0 hanggang 50 10 28 1680 6 3 2 8 8.6
06DR3370… 06DR3376… -40 hanggang 25 10 37.1 2225 6 3 2 8 5.7 9.2
06DM3370… 06DM3376… 0 hanggang 25 10 37.1 2225 6 3 2 8 8.7
06DA5372… 06DA5376… 0 hanggang 50 15 37.1 2225 6 3 2 8 8.7
06DR5410… 06DR5416… -40 hanggang 30 15 41 2460 6 3 2 8 5 9

Paglalarawan

Ang mga semi-hermetic compressor ng Carlyle 06D/E ay angkop na angkop para sa komersyal na pagpapalamig, air conditioning, paglamig ng proseso, at mga silid sa kapaligiran.Ang mga ito ay lubhang nababaluktot at maaaring gamitin kasama ng marami sa mga bagong HFC na nagpapalamig gaya ng R-507, R-404A, R-407C at R-134a, bilang karagdagan sa mga kumbensyonal na nagpapalamig (R-12, R-22, at R -502).Ang mga compressor ay maaaring patakbuhin sa 50 o 60 hertz.Marami sa mga kilalang tampok ng 06D/E compressor ay nakalista sa ibaba.
Mga Tampok:
– Ang high-flow, awtomatikong nababaligtad na oil pump ay nagbibigay ng positive-displacement oil lubrication.
– Ang crankcase venting system ay nagpapapantay sa presyon sa panahon ng start-up at tinitiyak ang pagbabalik ng langis sa sump.
– Ang sobrang laki ng sump ay nagtataglay ng labis na langis sa crankcase upang maiwasang bumaba ang mga antas sa ibaba ng ligtas na hanay ng pagpapadulas sa panahon ng pagbaha.
– Ang mga contour na piston ay nagpapababa ng mga clearance ng cylinder upang mapataas ang kapasidad at kahusayan ng compressor.
– Ang mga high-efficiency valve ay nagbibigay ng mas mataas na daloy ng nagpapalamig at mas mababang presyon.
– Elektronikong switch ng presyon ng langis.


  • Nakaraan:
  • Susunod:

  • Isulat ang iyong mensahe dito at ipadala ito sa amin