40HP Carlyle Carrier Compressors 06EA299600 għall-Arja Kundizzjonata
KOMPRESSOR CARLYLE D Serje
Carlyle | Servizz Carlyle | Temp. | Mutur | CFM | CFH | Nru. | Nru. | Potenzjal | Żejt | Temperatura Baxxa. | Med Temp. | |
Mudell OEM | Sostituzzjoni | Firxa | Daqs | of | of | Ħatt | Ħlas | EER | EER | |||
Numru | Mudell | R404a | HP | Cyl | Kapijiet | Stadji | Pint | R404a @ | R404a @ | |||
-0.003846154 | 20/110/65 | |||||||||||
06DM8080... | 06DM8086... | 0 sa 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090... | 06DR1086... | -40 sa 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130... | 06DR0136… | -40 sa 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130... | 06DM3136... | 0 sa 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160... | 06DR3166... | -40 sa 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160... | 06DM3166... | 0 sa 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180... | 06DR7186... | -40 sa 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182... | 06DS8186... | 0 sa 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200... | 06DR8206... | -40 sa 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240... | 06DR7246... | -40 sa 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250... | 06DR7256... | -40 sa 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242... | 06DS8246 | 0 sa 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252... | 06DS8256... | 0 sa 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280... | 06DR2286... | -40 sa 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282... | 06DS3286... | 0 sa 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370... | 06DR3376... | -40 sa 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370... | 06DM3376... | 0 sa 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372... | 06DA5376... | 0 sa 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410... | 06DR5416... | -40 sa 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
KOMPRESSOR CARLYLE ESeries
Carlyle | Servizz Carlyle | Temp. | Mutur | CFM | CFH | Nru. | Nru. | Potenzjal | Żejt | Temperatura Baxxa. | Med Temp. | |
Mudell OEM | Sostituzzjoni | Firxa | Daqs | of | of | Ħatt | Ħlas | EER | EER | |||
Numru | Mudell | R404a | HP | Cyl | Kapijiet | Stadji | Pint | R404a @ | R404a @ | |||
-0.003846154 | 20/110/65 | |||||||||||
06DM8080... | 06DM8086... | 0 sa 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090... | 06DR1086... | -40 sa 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130... | 06DR0136… | -40 sa 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130... | 06DM3136... | 0 sa 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160... | 06DR3166... | -40 sa 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160... | 06DM3166... | 0 sa 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180... | 06DR7186... | -40 sa 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182... | 06DS8186... | 0 sa 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200... | 06DR8206... | -40 sa 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240... | 06DR7246... | -40 sa 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250... | 06DR7256... | -40 sa 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242... | 06DS8246 | 0 sa 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252... | 06DS8256... | 0 sa 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280... | 06DR2286... | -40 sa 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282... | 06DS3286... | 0 sa 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370... | 06DR3376... | -40 sa 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370... | 06DM3376... | 0 sa 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372... | 06DA5376... | 0 sa 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410... | 06DR5416... | -40 sa 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
Deskrizzjoni
Il-kompressuri semi-ermetiċi Carlyle 06D/E huma idealment adattati għal refriġerazzjoni kummerċjali, arja kondizzjonata, tkessiħ tal-proċess, u kmamar ambjentali.Huma estremament flessibbli u jistgħu jintużaw ma 'ħafna mir-refriġeranti HFC ġodda bħal R-507, R-404A, R-407C u R-134a, minbarra r-refriġeranti konvenzjonali (R-12, R-22, u R). -502).Il-kompressuri jistgħu jitħaddmu f'50 jew 60 hertz.Ħafna mill-karatteristiċi prominenti tal-kompressuri 06D/E huma elenkati hawn taħt.
karatteristiċi:
– Il-pompa taż-żejt b'fluss għoli, awtomatikament riversibbli tipprovdi lubrikazzjoni taż-żejt b'spostament pożittiv.
– Is-sistema tal-ventilazzjoni tal-crankcase tqabbel il-pressjoni waqt l-istartjar u tiżgura r-ritorn taż-żejt fis-sump.
– Sump oversize iżomm żejt żejjed fil-crankcase biex jipprevjeni li l-livelli jinżlu taħt il-firxa tal-lubrikazzjoni sigura waqt bidu mgħarraq.
– Il-pistuni bil-kontorn ibaxxu t-tneħħija taċ-ċilindru biex iżidu l-kapaċità u l-effiċjenza tal-kompressur.
– Valvoli ta 'effiċjenza għolja jipprovdu fluss ta' refriġerant akbar u tnaqqis fil-pressjoni.
– Swiċċ elettroniku tal-pressjoni taż-żejt.