I-40HP Carlyle Carrier Compressors 06EA299600 ye-Air Conditioning
CARLYLE COMPRESSOR D Series
Carlyle | Carlyle Service | Temp. | Imoto | CFM | CFH | Hayi. | Hayi. | Okunokwenzeka | I-oyile | Ubushushu obuphantsi. | Med Temp. | |
Imodeli ye-OEM | Ukutshintshwa | Uluhlu | Ubungakanani | of | of | Ukothula | Ukuhlawulisa | EER | EER | |||
Inani | Umzekelo | R404a | HP | Cyl | Iintloko | Amanqanaba | Iipayinti | R404a @ | R404a @ | |||
-0.003846154 | 20/110/65 | |||||||||||
06DM8080... | 06DM8086... | 0 ukuya ku50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090... | 06DR1086... | -40 ukuya kwi-0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130... | 06DR0136... | -40 ukuya kwi-0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130... | 06DM3136... | 0 ukuya ku50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160... | 06DR3166... | -40 ukuya kuma-25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160... | 06DM3166... | 0 ukuya ku25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180... | 06DR7186... | -40 ukuya kwi-0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182... | 06DS8186... | 0 ukuya ku50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200... | 06DR8206... | -40 ukuya kuma-40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240... | 06DR7246... | -40 ukuya kuma-25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250... | 06DR7256... | -40 ukuya kuma-25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242... | 06DS8246 | 0 ukuya ku50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252... | 06DS8256... | 0 ukuya ku50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280... | 06DR2286... | -40 ukuya kwi-30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282... | 06DS3286... | 0 ukuya ku50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370... | 06DR3376... | -40 ukuya kuma-25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370... | 06DM3376... | 0 ukuya ku25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372... | 06DA5376... | 0 ukuya ku50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410... | 06DR5416... | -40 ukuya kwi-30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
CARLYLE COMPRESSOR ESeries
Carlyle | Carlyle Service | Temp. | Imoto | CFM | CFH | Hayi. | Hayi. | Okunokwenzeka | I-oyile | Ubushushu obuphantsi. | Med Temp. | |
Imodeli ye-OEM | Ukutshintshwa | Uluhlu | Ubungakanani | of | of | Ukothula | Ukuhlawulisa | EER | EER | |||
Inani | Umzekelo | R404a | HP | Cyl | Iintloko | Amanqanaba | Iipayinti | R404a @ | R404a @ | |||
-0.003846154 | 20/110/65 | |||||||||||
06DM8080... | 06DM8086... | 0 ukuya ku50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090... | 06DR1086... | -40 ukuya kwi-0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130... | 06DR0136... | -40 ukuya kwi-0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130... | 06DM3136... | 0 ukuya ku50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160... | 06DR3166... | -40 ukuya kuma-25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160... | 06DM3166... | 0 ukuya ku25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180... | 06DR7186... | -40 ukuya kwi-0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182... | 06DS8186... | 0 ukuya ku50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200... | 06DR8206... | -40 ukuya kuma-40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240... | 06DR7246... | -40 ukuya kuma-25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250... | 06DR7256... | -40 ukuya kuma-25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242... | 06DS8246 | 0 ukuya ku50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252... | 06DS8256... | 0 ukuya ku50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280... | 06DR2286... | -40 ukuya kwi-30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282... | 06DS3286... | 0 ukuya ku50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370... | 06DR3376... | -40 ukuya kuma-25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370... | 06DM3376... | 0 ukuya ku25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372... | 06DA5376... | 0 ukuya ku50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410... | 06DR5416... | -40 ukuya kwi-30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
Inkcazo
Iicompressor zeCarlyle 06D/E zesemi-hermetic zifaneleke ngokufanelekileyo kwifriji yorhwebo, i-air conditioning, inkqubo yokupholisa, kunye namagumbi okusingqongileyo.Zibhetyebhetye kakhulu kwaye zinokusetyenziswa kunye neefriji ezininzi ze-HFC ezintsha ezifana ne-R-507, i-R-404A, i-R-407C kunye ne-R-134a, ukongeza kwiifriji eziqhelekileyo (R-12, R-22, kunye ne-R -502).Iicompressors zinokusebenza kwi-50 okanye i-60 hertz.Uninzi lweempawu ezibalaseleyo ze-06D/E compressors zidweliswe ngezantsi.
Iimbonakalo:
-Ukuhamba okuphezulu, impompo yeoli ebuyiselwa umva ngokuzenzekelayo ibonelela nge-lubrication yeoli ene-positive-displacement.
-Inkqubo yokukhupha i-Crankcase ilingana noxinzelelo ngexesha lokuqalisa kwaye iqinisekisa ukubuya kweoli kwi-sump.
-I-Oversize sump ibamba i-oyile eyongezelelweyo kwi-crankcase ukunqanda ukuba amanqanaba ehle ngaphantsi koluhlu lokuthambisa olukhuselekileyo ngexesha lokuqalisa kwezikhukhula.
-Iipiston ezigudileyo ezisezantsi zokukhutshwa kwe-cylinder ukwandisa umthamo wecompressor kunye nokusebenza kakuhle.
-Iivalve ezisebenza kakuhle kakhulu zibonelela ngokunyuka kwe-refrigerant flow and low pressure drops.
-Ukutshintsha koxinzelelo lwe-oyile ye-elektroniki.