COMPRESSOR CARLYLE Sèrie D
Carlyle | Servei Carlyle | Temp. | Motor | CFM | CFH | No. | No. | Potencial | Oli | Baixa temperatura. | Med Temp. | |
Model OEM | Substitució | Interval | Mida | of | of | Descàrrega | Càrrega | EER | EER | |||
Número | Model | R404a | HP | cil | Caps | Etapes | Pintes | R404a @ | R404a @ | |||
-0,003846154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 a 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 a 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 a 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 a 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 a 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 a 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 a 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 a 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 a 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 a 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 a 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 a 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 a 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 a 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 a 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 a 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 a 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376… | 0 a 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 a 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
CARLYLE COMPRESSOR ESeries
Carlyle | Servei Carlyle | Temp. | Motor | CFM | CFH | No. | No. | Potencial | Oli | Baixa temperatura. | Med Temp. | |
Model OEM | Substitució | Interval | Mida | of | of | Descàrrega | Càrrega | EER | EER | |||
Número | Model | R404a | HP | cil | Caps | Etapes | Pintes | R404a @ | R404a @ | |||
-0,003846154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 a 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 a 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 a 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 a 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 a 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 a 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 a 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 a 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 a 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 a 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 a 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 a 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 a 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 a 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 a 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 a 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 a 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376… | 0 a 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 a 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
Descripció
Els compressors semihermètics Carlyle 06D/E són ideals per a la refrigeració comercial, l'aire condicionat, la refrigeració de processos i les cambres ambientals.Són extremadament flexibles i es poden utilitzar amb molts dels nous refrigerants HFC com R-507, R-404A, R-407C i R-134a, a més dels refrigerants convencionals (R-12, R-22 i R). -502).Els compressors poden funcionar a 50 o 60 hertz.A continuació s'enumeren moltes de les característiques destacades dels compressors 06D/E.
Característiques:
- La bomba d'oli reversible automàticament d'alt cabal proporciona una lubricació d'oli de desplaçament positiu.
- El sistema de ventilació del cárter iguala la pressió durant la posada en marxa i assegura el retorn de l'oli al carter.
- El carter de grans dimensions conté oli addicional al cárter per evitar que els nivells caiguin per sota del rang de lubricació segura durant els arrencades inundats.
– Els pistons contornejats redueixen els jocs del cilindre per augmentar la capacitat i l'eficiència del compressor.
– Les vàlvules d'alta eficiència proporcionen un major cabal de refrigerant i menors caigudes de pressió.
– Pressostat electrònic d'oli.