40HP Carlyle Carrier Compressors 06EA299600 maka ntụ oyi

Nkọwa dị mkpirikpi:

Brand: Onye na-ebu
Ụdị: 06EA299600
Ike: 40 hp
Silinda: 6
Ike (m3 / h): 140.40 m3 / h
Ọnụ mmanụ: 9 l
Net arọ: 236 kg
Igwe nju oyi: R22


Nkọwa ngwaahịa

Mkpado ngwaahịa

CARLYLE COMPRESSOR D Series

Carlyle Ọrụ Carlyle Okpomọkụ moto CFM CFH Mba. Mba. Enwere ike Mmanụ Obere okpomọkụ. Med Temp.
Ụdị OEM Ndochi Oke Nha of of Na-ebupụ Ebo EER EER
Nọmba Nlereanya R404a HP Cyl Isi Usoro Pint R404a @ R404a @
-0.003846154 20/110/65
06DM8080… 06DM8086… 0 ruo 50 3 8 480 2 1 0 3 8.4
06DR1090… 06DR1086… -40 ruo 0 2 8.7 522 2 1 0 3 5.4
06DR0130… 06DR0136… -40 ruo 0 3 13 786 4 2 1 4.5 5.3
06DM3130… 06DM3136… 0 ruo 50 5 13 786 4 2 1 4.5 9.3
06DR3160… 06DR3166… -40 ruo 25 5 15.9 954 4 2 1 4.5 5.4 9.3
06DM3160… 06DM3166… 0 ruo 25 5 15.9 954 4 2 1 4.5 9
06DR7180… 06DR7186… -40 ruo 0 5 18.3 1100 4 2 1 5.5 5.5
06DA8182… 06DS8186… 0 ruo 50 6 1/2 18.3 1100 4 2 1 5.5 8.6
06DR8200… 06DR8206… -40 ruo 40 6 1/2 20 1200 4 2 1 5.5 5.6 9.4
06DR7240… 06DR7246… -40 ruo 25 6 1/2 23.9 1435 6 3 2 8 5.6 9.2
06DR7250… 06DR7256… -40 ruo 25 6 1/2 23.9 1435 6 3 2 8 5.6 9.2
06DA8242… 06DS8246 0 ruo 50 7 1/2 23.9 1435 6 3 2 8 8.6
06DA8252… 06DS8256… 0 ruo 50 7 1/2 23.9 1435 6 3 2 8 8.6
06DR2280… 06DR2286… -40 ruo 30 7 1/2 28 1680 6 3 2 8 5.7 9.2
06DA3282… 06DS3286… 0 ruo 50 10 28 1680 6 3 2 8 8.6
06DR3370… 06DR3376… -40 ruo 25 10 37.1 2225 6 3 2 8 5.7 9.2
06DM3370… 06DM3376… 0 ruo 25 10 37.1 2225 6 3 2 8 8.7
06DA5372… 06DA5376… 0 ruo 50 15 37.1 2225 6 3 2 8 8.7
06DR5410… 06DR5416… -40 ruo 30 15 41 2460 6 3 2 8 5 9

CARLYLE COMPRESSOR ESeries

Carlyle Ọrụ Carlyle Okpomọkụ moto CFM CFH Mba. Mba. Enwere ike Mmanụ Obere okpomọkụ. Med Temp.
Ụdị OEM Ndochi Oke Nha of of Na-ebupụ Ebo EER EER
Nọmba Nlereanya R404a HP Cyl Isi Usoro Pint R404a @ R404a @
-0.003846154 20/110/65
06DM8080… 06DM8086… 0 ruo 50 3 8 480 2 1 0 3 8.4
06DR1090… 06DR1086… -40 ruo 0 2 8.7 522 2 1 0 3 5.4
06DR0130… 06DR0136… -40 ruo 0 3 13 786 4 2 1 4.5 5.3
06DM3130… 06DM3136… 0 ruo 50 5 13 786 4 2 1 4.5 9.3
06DR3160… 06DR3166… -40 ruo 25 5 15.9 954 4 2 1 4.5 5.4 9.3
06DM3160… 06DM3166… 0 ruo 25 5 15.9 954 4 2 1 4.5 9
06DR7180… 06DR7186… -40 ruo 0 5 18.3 1100 4 2 1 5.5 5.5
06DA8182… 06DS8186… 0 ruo 50 6 1/2 18.3 1100 4 2 1 5.5 8.6
06DR8200… 06DR8206… -40 ruo 40 6 1/2 20 1200 4 2 1 5.5 5.6 9.4
06DR7240… 06DR7246… -40 ruo 25 6 1/2 23.9 1435 6 3 2 8 5.6 9.2
06DR7250… 06DR7256… -40 ruo 25 6 1/2 23.9 1435 6 3 2 8 5.6 9.2
06DA8242… 06DS8246 0 ruo 50 7 1/2 23.9 1435 6 3 2 8 8.6
06DA8252… 06DS8256… 0 ruo 50 7 1/2 23.9 1435 6 3 2 8 8.6
06DR2280… 06DR2286… -40 ruo 30 7 1/2 28 1680 6 3 2 8 5.7 9.2
06DA3282… 06DS3286… 0 ruo 50 10 28 1680 6 3 2 8 8.6
06DR3370… 06DR3376… -40 ruo 25 10 37.1 2225 6 3 2 8 5.7 9.2
06DM3370… 06DM3376… 0 ruo 25 10 37.1 2225 6 3 2 8 8.7
06DA5372… 06DA5376… 0 ruo 50 15 37.1 2225 6 3 2 8 8.7
06DR5410… 06DR5416… -40 ruo 30 15 41 2460 6 3 2 8 5 9

Nkọwa

Carlyle 06D/E semi-hermetic compressors dabara nke ọma maka refrigeration azụmahịa, ntụ oyi, nhazi usoro, na ụlọ gburugburu.Ha na-agbanwe nke ukwuu ma enwere ike iji ya na ọtụtụ refrigerant ọhụrụ HFC dị ka R-507, R-404A, R-407C na R-134a, na mgbakwunye na refrigerant ndị a na-ahụkarị (R-12, R-22, na R) -502).Enwere ike iji compressors na 50 ma ọ bụ 60 hertz.Ọtụtụ njirimara ama ama nke compressors 06D/E ka edepụtara n'okpuru.
Atụmatụ:
- Igwe mmiri dị elu, mgbapụta mmanụ na-agbanwe agbanwe na-enye mmanu mmanu mmanu mmanu.
- Sistemụ ikuku crankcase na-eme ka nrụgide dị n'oge mmalite ma kwenye na nlọghachi mmanụ na sump.
- Oversize sump na-ejide mmanụ ọzọ na crankcase iji gbochie ọkwa ịdaba n'okpuru oke mmanu mmanu n'oge mmalite ide mmiri.
- Pistons contoured na-ebelata mkpochapụ cylinder iji mee ka ikike compressor na arụmọrụ dị elu.
- valvụ dị elu na-arụ ọrụ nke ọma na-enye mmụba refrigerant na-agbadata nrụgide dị ala.
– Eletrọnịkị mmanụ-ngbanwe mgba ọkụ.


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a ziga anyị ya