40HP Carlyle Portitorem Compressors 06EA299600 pro Aeris condicionibus
CARLYLE COMPRESSOR D Series
Carlyle | Carlyle Service | Temp. | Motor | CFM | CFH | Nec. | Nec. | Potentia | Oleum | Low Temp. | Med Temp. | |
Altera Model | Replacement | Range | Magnitudo | of | of | Unloading | Crimen | EER | EER | |||
Numerus | Model | R404a | HP | Cyl | Capita | Gradus | Pints | R404a @ | R404a @ | |||
-0.00384154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 ad 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 ad 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 ad 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 ad 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 ad 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 ad 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 ad 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 ad 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 ad 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 ad 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 ad 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 ad 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 ad 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 ad 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 ad 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 ad 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 ad 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376... | 0 ad 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 ad 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
CARLYLE COMPRESSOR ESeries
Carlyle | Carlyle Service | Temp. | Motor | CFM | CFH | Nec. | Nec. | Potentia | Oleum | Low Temp. | Med Temp. | |
Altera Model | Replacement | Range | Magnitudo | of | of | Unloading | Crimen | EER | EER | |||
Numerus | Model | R404a | HP | Cyl | Capita | Gradus | Pints | R404a @ | R404a @ | |||
-0.00384154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 ad 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 ad 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 ad 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 ad 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 ad 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 ad 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 ad 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 ad 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 ad 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 ad 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 ad 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 ad 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 ad 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 ad 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 ad 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 ad 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 ad 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376... | 0 ad 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 ad 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
Descriptio
Carlyle 06D/E compressores semi-hermetici speciatim apti sunt ad refrigerationem commercialem, condiciones aeris, refrigerationem processus, et cubicula environmentalia.Valde flexibilia sunt et cum multis refrigerantibus novis HFC utantur uti R-507, R-404A, R-407C et R-134a, praeter refrigerantia conventionalia (R-12, R-22, R). -502).Compressores operari possunt ad 50 vel 60 hertz.Multae lineamenta prominentia 06D/E compressorum infra recensentur.
Features:
- Summus-fluxus, sponte convertitur sentinam olei positivi-displacentiam praebet oleum lubricationis.
- Crankcase ratio arcendi coaequat pressuram in satus-sursum et oleum sumptionis redituum confirmat.
- Oversize sump tenet oleum extra in crankcase ne gradus infra lapsus tutum lubrication range in inundatione incipit.
– Contoured pistores inferiores cylindrici Clearances ad facultatem et efficientiam compressor augendam.
- Summus valvulae efficientiam augendam praebent fluxum refrigerandi et pressionis inferioris guttae.
- Pressurae oleum Electronic switch.