40HP Carlyle Carrier Compressors 06EA299600 untuk AC
KOMPRESOR CARLYLE Seri D
Carlyle | Layanan Carlyle | Suhu. | Motor | CFM | CFH | TIDAK. | TIDAK. | Potensi | Minyak | Suhu Rendah. | Suhu Medis. | |
Model OEM | Penggantian | Jangkauan | Ukuran | of | of | Bongkar | Mengenakan biaya | EER | EER | |||
Nomor | Model | R404a | HP | Sil | Kepala | Tahapan | Pint | R404a @ | R404a @ | |||
-0,003846154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 hingga 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 ke 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 ke 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 hingga 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 hingga 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 sampai 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 ke 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 hingga 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 hingga 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 hingga 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 hingga 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 hingga 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 hingga 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 hingga 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 hingga 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 hingga 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 sampai 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376… | 0 hingga 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 hingga 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
Seri KOMPRESOR CARLYLE
Carlyle | Layanan Carlyle | Suhu. | Motor | CFM | CFH | TIDAK. | TIDAK. | Potensi | Minyak | Suhu Rendah. | Suhu Medis. | |
Model OEM | Penggantian | Jangkauan | Ukuran | of | of | Bongkar | Mengenakan biaya | EER | EER | |||
Nomor | Model | R404a | HP | Sil | Kepala | Tahapan | Pint | R404a @ | R404a @ | |||
-0,003846154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 hingga 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 ke 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 ke 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 hingga 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 hingga 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 sampai 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 ke 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 hingga 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 hingga 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 hingga 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 hingga 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 hingga 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 hingga 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 hingga 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 hingga 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 hingga 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 sampai 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376… | 0 hingga 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 hingga 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
Keterangan
Kompresor semi-kedap udara Carlyle 06D/E cocok untuk pendinginan komersial, AC, pendinginan proses, dan ruang lingkungan.Mereka sangat fleksibel dan dapat digunakan dengan banyak refrigeran HFC baru seperti R-507, R-404A, R-407C dan R-134a, selain refrigeran konvensional (R-12, R-22, dan R-22). -502).Kompresor dapat dioperasikan pada 50 atau 60 hertz.Banyak fitur menonjol dari kompresor 06D/E tercantum di bawah ini.
Fitur:
– Pompa oli dengan aliran tinggi dan dapat dibalik secara otomatis memberikan pelumasan oli perpindahan positif.
– Sistem ventilasi bak mesin menyamakan tekanan selama penyalaan dan memastikan oli kembali ke bak.
– Bak penampung yang terlalu besar menampung oli ekstra di bak mesin untuk mencegah level turun di bawah rentang pelumasan yang aman selama start yang banjir.
– Piston berkontur menurunkan jarak bebas silinder untuk meningkatkan kapasitas dan efisiensi kompresor.
– Katup efisiensi tinggi memberikan peningkatan aliran zat pendingin dan penurunan tekanan yang lebih rendah.
– Sakelar tekanan oli elektronik.