Bitzer compressor

  • 30hp Bitzer 6G-30.2-40P Compressor Commercial refrigerator Compressor R134a na ngwaahịa.

    30hp Bitzer 6G-30.2-40P Compressor Commercial refrigerator Compressor R134a na ngwaahịa.

    Nkọwapụta Bitzer 6G-30.2-40P

    Ike: 22KW
    Ike: 380V/440V-50HZ/60HZ
    Dayameta cylinder (mm): 75
    Ọkpụkpụ (mm): 55
    Ọnụọgụ nke cylinders: 6
    Oke mkpofu: 126.8m3 / h
    Ogo mgbago ụkwụ: 305mmx381mm
    Akụkụ (mm): ogologo 790 obosara 503 elu 443
    Dayameta ọkpọkọ dị n'ime (mm): 54
    Dayameta anwụrụ ọkụ dị n'ime (mm): 35
    Ọnụ mmanụ (liter): 4.75
    Kwesịrị ekwesị maka refrigerant: R134a R404A R507A R407C

    Anyị nwekwara ike ịnye ụdị ndị a

    (一)4PCS-102(Y)) 4PES-12(Y) 4TES-12(Y) 4PES-12(Y) 4PES-15(Y)

    4NES-14(Y) 4NES-20(Y) 4JE-15(Y) 4JE-22(Y) 4HE-18(Y)

    4HE-25(Y) 4GE-23(Y) 4GE-30(Y) 6JE-25(Y) 6JE-33(Y)

    6HE-25(Y) 6HE-35(Y) 6GE-30(Y) 6GE-40(Y) 6FE-40(Y)

    6FE-50(Y) 8GE-50(Y) 8GE-60(Y) 8FE-60(Y) 4TCS-12.2(Y)

    4PCS-10.2(Y) 4PCS-15.2(Y) NCS-12.2(Y) NCS-20.2(Y) 4J-13.2(Y)

    4J-22.2(Y) 4H-15.2(Y) 4H-25.2(Y) 4G-20.2(Y) 4G-30.2(Y)

    6J-22.2(Y) 6J-33.2(Y) 6H-25.2(Y) 6H-35.2(Y) 6 G-30.2(Y)

    6G-40.2(Y) 6F-40.2(Y) 6F-50.2(Y) 8GC-50.2(Y) 8GC-60.2(Y) 8FC-60.2(Y)

     

    (Ike) abụọ ogbo bitzer reciprocating compressors

    S4G-12.2Y, S6J-16.2Y S4N-8.2Y

    S6H-20.2(Y) S6G-25.2(Y) S6F-30.2(Y)

    Bizer nke nwere nkeji abụọ nwere ikike 4KW-44KW

    Usoro nke compressors a bụ nsonaazụ nyocha na mmepe buru ibu dabere na ahụmịhe afọ n'ịmepụta piston compressors nke ọma na ntụkwasị obi.
    Emepụtala kọmpat ndị a ma kwalite maka refrigerants ọzọ, ọkachasị HCFC R22, HFC R404A, na R507A, na nkọwa ụfọdụ dị mkpa.
    N'iji akụkụ ndị a nwapụtara kemgbe ọtụtụ afọ, ọ bụ ngwaahịa nwere usoro a pụrụ ịdabere na ya nke a na-ejikarị eme ihe n'ọtụtụ ebe.
    Nkwekọrịta nke ụzọ ikuku na-asọpụta na valvụ efere ihe owuwu na ngwa cryogenic, yana nke a haziri nke ọma nke ọgbọ nke abụọ na ihe ndị na-akwọ ụgbọala maka arụmọrụ kachasị elu, na-arụpụta arụmọrụ dị elu karịa usoro cryogenic gara aga.
    Usoro mkpakọ ụwa niile maka HFC chlorine na friji HCFC
    Ntughari iji HFC refrigerant:
    ● Jiri mmanụ polyester kwadoro nke Bizer kwadoro (nsochie ihe nrịbama nke nwere "Y")
    Atụmatụ nhazi kachasị mkpa: □ Ụzọ gas dị mkpirikpi
    ● Nnukwu oghere imi ● Obere okpomọkụ mgbanwe □ Ebere efere valvụ a pụrụ ịdabere na ya
    ● Mmetụta eguzogide mmiri ígwè valvụ efere
    Obere oghere chọrọ
    Nha dị oke kọmpat □ Obere ịma jijiji na mkpọtụ dị ala
    ● Ihe owuwu 4-cylinder na 6-cylinder nwere nhazi nguzozi oke oke, ọkachasị arụ ọrụ dị jụụ □ Ikike jụrụ oyi na obere ume ike.
    ● Efere valvụ na-arụ ọrụ dị elu ● Opekempe nkwụsị nke etiti nwụrụ anwụ ● Nnukwu arụmọrụ nnukwu moto olu □ Ihe ndị na-akwọ ụgbọala na-adịgide adịgide
    ● Eccentric shafts na crankshafts na ebe ndị siri ike ● Akara mkpuchi isi na nnukwu nfuli mmanụ ● Patent mmanụ nkwụghachi usoro na-eme ka ọnụ ọgụgụ mmanụ dị ala dị ala ● obere esemokwu na-ebu shei na pistons aluminom ● Piston mgbanaka na chrome siri ike na-ebupụta elu ● Pụrụ crank pin bearing. shells □ Nrụgide usoro mmanye mmanu mmanu
    ● Nweta mgbapụta mmanụ gia nke nwere ike ịrụ ọrụ n'akụkụ abụọ ahụ □ Nnukwu moto arụnyere
    ● gas jụrụ oyi
    Akụkụ rotor na stator kachasị mma nwere arụmọrụ kachasị elu yana ihe ike □ igbe nkwụsị ọkwa ọkwa IP54
    Nhọrọ IP66 □ Ngwaọrụ nchebe moto eletrọnịkị
    ● Jiri ihe mmetụta PTC iji nyochaa okpomọkụ moto ● Nchedo okpomọkụ (nhọrọ) □ valvụ nchekwa nrụgide dị iche arụnyere □ Sistemụ ntụtụ mmiri na-ajụ oyi na etiti.
    valvụ igwe TX nhọrọ
    ● Họrọ usoro CIC nke eletrọnịkị na-achịkwa maka R22
    Nhọrọ:
    ● Subcooler mmiri arụnyere ● ihe mmetụta nchebe ikpochapụ okpomọkụ
    ● Ngwaọrụ nchebe moto nwere ọrụ ndị ọzọ (INT389) ● Crankcase heater ● Mgbanwe mkpuchi mmanụ ● valve mmezi mmanụ.

     

     

     

     

     

     

     

     

     

     

     

  • 140HP bitzer ịghasa refrigratiom compressor CSH8693-140Y maka ụlọ ọrụ refrigeration.

    140HP bitzer ịghasa refrigratiom compressor CSH8693-140Y maka ụlọ ọrụ refrigeration.

    Ụdị Compressor: CSH8693-140Y
    friji: R134A
    Nkwagharị (m3/h): 535m3/h
    Ntinye ike kachasị: 148kw
    Ịnyịnya ike (hp): 140 HP
    Oke ikuku: 50/50

  • 40HP bitzer na-emegharị igwe nju oyi nke azụmahịa 6GE-40Y maka ngalaba condensing

    40HP bitzer na-emegharị igwe nju oyi nke azụmahịa 6GE-40Y maka ngalaba condensing

    Ụdị Compressor: 6GE-40Y

    ngwa nju oyi: R404A/R22

    Ngbanwe (m3 / h): 126.8 m3 / h

    Oke ike: 45.1kw

    Ịnyịnya ike (hp): 40 HP

    Ọnụ mmanụ: 4.75L

  • CSH6563-60Y-40P CSH7563-80-40P CSH8571 50-240hp ịghasa refrigeration bitzer

    CSH6563-60Y-40P CSH7563-80-40P CSH8571 50-240hp ịghasa refrigeration bitzer

    Ụdị: CSH7563-80-40P

    Ọnụ mmanụ: 15L

    Arọ: 520KGS

    Ike inyinya: 80HP

    Ụdị: Kpọrọ

     

     

     

     

     

  • 50HP Bitzer Ihe Ntugharị Ntugharị Semi-hermetic 6FE-50Y-40P

    50HP Bitzer Ihe Ntugharị Ntugharị Semi-hermetic 6FE-50Y-40P

    Eletriki: Akụkụ ikuku
    Voltaji: 380v-420V/3 ph/50hz – 440v-480v/3 ph/60hz
    Nha ịbụibu: 241kg
    Akụkụ:
    790 (L) x 503 (W) x 443 (H)

  • 140HP Bitzer Refrigeration Screw Compressor CSH – CSH8573-140(Y)

    140HP Bitzer Refrigeration Screw Compressor CSH – CSH8573-140(Y)

    Data teknụzụ
    Ntugharị (2900 RPM 50 Hz) 410 m³/h
    Ntugharị (3500 RPM 60 Hz) 495 m³/h
    Ibu 870 kg
    Oke.nrụgide (LP/HP) 19/28 mmanya
    Ahịrị mmịpụta njikọ DN 100
    Ahịrị nkwụsị njikọ 76 mm - 3 1/8"
    Ụdị mmanụ R1234yf/R1234ze(E)/R450A/R513A BSE170 (Nhọrọ)
    Ụdị mmanụ R134a/R407C/R404A/R507A/R407A/R407F BSE170 (Nhọrọ)
    Ụdị mmanụ R22 B320SH (Standard)

  • Bitzer 6FE-50Y-40P compressor

    Bitzer 6FE-50Y-40P compressor

    Nkọwapụta

    Eletriki: Akụkụ ikuku
    Voltaji: 380v-420V/3 ph/50hz – 440v-480v/3 ph/60hz
    Nha ịbụibu: 241kg
    Akụkụ:
    790 (L) x 503 (W) x 443 (H)

  • 40HP Biter refrigeration compressor 6GE-40Y-40P maka chiller

    40HP Biter refrigeration compressor 6GE-40Y-40P maka chiller

    Data teknụzụ
    Ntugharị (1450 RPM 50Hz) 126,8 m³/h
    Ntugharị (1750 RPM 60Hz) 153,0 m³/h
    Ọnụ ọgụgụ cylinder x gbara x strok 6 x 75 mm x 55 mm
    Ibu 238kg
    Oke.nrụgide (LP/HP) 19/32 mmanya
    Ahịrị mmanye njikọ 54 mm - 2 1/8”
    Ahịrị nkwụsị njikọ 35 mm - 1 3/8"

  • Igwe nju oyi Semi hermetic compressor 2-ogbo S6F-30.2Y

    Igwe nju oyi Semi hermetic compressor 2-ogbo S6F-30.2Y

    • Ụdị: S6F-30.2Y
    • Ngbanwe na 1450 min-1 : 101,1 (LP) 50,5 (HP)
    • Ọnụọgụ nke cylinders: 6
    • Ọnụ mmanụ: 4,75 dm3
  • Bitzer 4GE-30Y-40P ọkara-hermetic reciprocating compressor

    Bitzer 4GE-30Y-40P ọkara-hermetic reciprocating compressor

    Oke ECOLINE bụ ọganihu okike nke ihe egosipụtara, siri ike na nke siri ike na-emegharị ihe na-emeghachi omume nke ọkara nke sitere na BITZER.Ọ na-ejikọta arụmọrụ dị elu, na-agba ọsọ dị mma, ọtụtụ ngwa ngwa, mgbanwe na nhọrọ refrigerant, nhazi siri ike na ntụkwasị obi dị elu.

    • Ụdị moto: 1
    • Nchụpụ na 1450 min-1: 84,6
    • Ọnụọgụ nke cylinders: 4