Kombaresarada qaadaha 3 wejiga kombaresarka ZMD26KVE-TFD, qaybo refer, kombaresarada King thermo ZMD26KVE-TFD iib kulul

Taxadirrada isticmaalka ZMD26KVE-TFD kombastarka duubista

1. Xagasha u janjeerta ee rakibaadda kombaresarada waa in aanay ka badnaan 5 darajo;Magaca kombaresarada waa in lagu calaamadiyaa saliid silcin joogto ah si loo hubiyo in cabbirada korontada iyo magaca kombaresarada ay iswaafaqayaan.Compressor-ku waa in lagu buuxiyaa nitrogen qalalan marka laga baxayo warshadda, iyo cadaadiska ku jira kombaresarada waa in la sii daayaa ka hor inta aan la isku xirin kombaresarka ZMD26KVE-TFD.

2. Inta lagu jiro ogaanshaha dheecaanka ee nidaamka qaboojiyaha iyo hawlgalka kombaresarada, cadaadiska ugu badan waa inuusan ka badnaan cadaadiska lagu qeexay magaca kombaresarada.Ha u isticmaalin hawo si aad u tijaabiso socodsiinta kombaresarka, sababtoo ah ZMD26KVE-TFD refer kombaresarka hawada cadaadiska sare leh iyo saliidda ayaa isku dhafan, gaaska isku dhafan ee cadaadiska sarreeya ayaa laga yaabaa inuu qarxo heerkulka sare ee dekedda qiiqa vortex-ka, taasoo keentay dhaawaca kombaresarada.

3. Hubi in tuubooyinka nuugista iyo qiiqa ay furan yihiin ka hor inta aanad bilaabin kombarada.Aad bay muhiim u tahay in si buuxda loo furo valve qiiqa ka hor inta aan la bilaabin kombaresarka.Haddi ZMD26KVE-TFD refer kombaresarka waalka qiiqa aan si buuxda loo furin, cadaadis sare oo khatar ah iyo heerkul sare ayaa ka dhalan doona kombaresarka.

4. Cadaadiska jabinta ugu badan ee nidaamku kama badna 28bar.Waxaa lagu talinayaa in dib-u-dejinta gacanta lagu sameeyo ka dib marka cadaadiska sare la gooyo, si gebi ahaanba meesha looga saaro cilladda.Qiimaha goobta goynta ee dareemaha cadaadiska hoose looma ogola inuu ka hooseeyo 0.1bar.

5. Ha isku darin saliidda ester-ka, saliidda macdanta ama alkylbenzene.Compressor-ka ZMD26KVE-TFD waxaa lagu shubay saliid saliid ah ka hor inta uusan ka tagin warshadda.Compressor R404A wuxuu isticmaalaa POE synthetic ester oil, iyo kombaresarada R22 waxay isticmaashaa saliid macdan ah oo 3GS ah.Magaca kombaresarka ayaa tilmaamaya mugga buuxinta saliidda ee bilowga ah kahor dhalmada.Mugga buuxinta goobta wuxuu noqon karaa ilaa 100ml wax ka yar mugga buuxinta bilowga ah.

6. ZMD26KVE-TFD refer compressor inta lagu jiro alxanka dhuumaha, nitrogen waa in lagu buuxiyaa gudaha dhuumaha si looga ilaaliyo miisaanka oksaydhka inuu xannibo nidaamka.Wax kasta oo alxanka ah oo naxaas ah iyo qalin ah ayaa loo isticmaali karaa alxanka, gaar ahaan ka kooban 45% electrode qalin ah, si loo helo tayada alxanka ugu fiican.Waxaa lagu talinayaa in lagu duubo tuubooyinka nuugista iyo qiiqa maro qoyan ka hor alxanka.

7. Marka kombasarruhu uu ordo laakiin kala duwanaanshaha cadaadiska aan la ogaan karin ama dhawaaqa ordaya uu aad u badan yahay.Waxay noqon kartaa in isku xirka saddexda weji ee kombaresarka U, V iyo W uu khaldan yahay, oo laba ka mid ah ay u baahan yihiin in la beddelo.


Waqtiga boostada: Mar-16-2023