Kombaresarada Carlyle

  • RSH105GD01, RSH105GR01, RSH105GA01, qaada r134a kombaresarada, weelka refer 69NT40-541-001 kombaresarada

    RSH105GD01, RSH105GR01, RSH105GA01, qaada r134a kombaresarada, weelka refer 69NT40-541-001 kombaresarada

    kombaresarada sidaha, qaybta NO.18-10134-23 kombaresarada rog roga qaybaha side refer

    RSH105GD01,RSH105GR01
    awoodda faraska: 10 hp
    isha korontada: 440-460V/3/60Hz
    400V/3ph/50hz
    LRA:80
    qaboojiyaha: r134a/r407c/r404a
    Maxay tahay in fiiro gaar ah loo yeesho dahaarka kaydinta qabowga iyo ilaalinta tamarta?kombaresarada sidaha r134a duubista RSH105GD01
    Sababtoo ah sifooyinka kor ku xusan ee dhismayaasha kaydinta qabow, marka lagu daro dahaarka adag, shaabadeynta, adkeysiga, iyo caabbinta dhaxan ee naqshadeynta iyo dhismaha si loo hubiyo tayada dhismaha, isticmaalka maalinlaha ah iyo maamulka, maareynta sayniska iyo wax soo saarka badbaadada leh waa in sidoo kale la hirgeliyaa iyada oo ku saleysan sifooyinka kaydinta qabow si ay u kordhiso nolosheeda adeegga, yaraynta kharashka wax soo saarka, badbaadinta kharashka dayactirka, iyo hagaajinta hufnaanta dhaqaalaha ganacsiga.Kaydinta qabowgu waa dhismo gaar ah oo loo isticmaalo qaboojinta cuntada iyo qaboojiyaha, iyo in lagu ilaaliyo heerkulka hooseeya.Compressors-ka qaada waxa loo adeegsadaa maraakiibta, marawaxada qulqulka axial qaro weyn ayaa lagu rakibay sagxadaha, darbiyada, iyo saqafyada bakhaarka.
    sidaha r134a kombaresarka RSH105GD01
    Compressors Carrier waxay dhaliyaan kulayl, iyo cilad-baadhista kombaresarada siday.Marka laga eego dhinaca ilaalinta tamarta, waxaa lagama maarmaan ah in la yareeyo wakhtiga bilawga ah iyo tirada cutubyada, Si kastaba ha ahaatee, kaydinta miraha iyo khudradda dhabta ah, habka hawlgalka ee labadaba dhaqaale iyo tayada badeecadu waa: marka la soo galo bakhaarka, dhammaan qulqulka axial marawaxadaha waa la shiday, waxaana la isticmaalaa qalabka kombaresarada qaadaha.Ka dib marka heerkulku xasilo, tirada unugyada la furay ayaa la dhimay, shuruudaha heerkulka adag ayaa lagu soo rogay noocyada kaydinta.Si loo hubiyo heerkulka isku midka ah ee u dhexeeya qaybaha sare iyo hoose, 1-2 marawaxadaha qulqulka axial ayaa wali shaqeynaya marka qaboojiyaha iyo sahayda dareeraha la joojiyo.Lakabka aan qoyaanka lahayn iyo lakabka dahaarka ee kombaresarada ayaa guud ahaan lagu qiimeeyaa iyadoo la adeegsanayo hababka tijaabada nolosha la dedejiyey ee nolosha shaqada ee kombaresarada.
    kombaresarada sidaha RSH105GD01
    Hababka sida caadiga ah loo isticmaalo waxaa ka mid ah 68t test xirashada xawaaraha, 1000h, 2000h ama xitaa imtixaanka nolosha dheer, 2000 ', iyo saacadda imtixaanka nolosha, kaas oo sidoo kale qiimeyn kara waafaqid ee alaabta kala duwan.

     

  • 40HP Carlyle Compressors 06EA299600 ee qaboojinta hawada

    40HP Carlyle Compressors 06EA299600 ee qaboojinta hawada

    Sumadda: Qaade
    Model: 06EA299600
    Awoodda: 40 hp
    Silinder: 6
    Awoodda (m3/h): 140.40 m3/h
    Qiimaha saliidda: 9 L
    Miisaanka saafiga ah: 236 kg
    Qaboojiyaha: R22

  • Qolka Qabow / Qaboojiyaha qaboojiyaha carlyle 06E Qaboojiyaha qaboojiyaha 06EA265,06EA275,06EA565

    Qolka Qabow / Qaboojiyaha qaboojiyaha carlyle 06E Qaboojiyaha qaboojiyaha 06EA265,06EA275,06EA565

    Qaababka la heli karo

    06ER4506A0, 06ER4656A0, 06ER4756A0, 06ER4756A0, 06EM4506A0, 06EA5656A0, 06EM4756A0, 06EM4996A0, 06EA5506A0,6EF 06EA5756A0, 06EF5756A0, 06EA5996A0, 06EF5996A0, 06ER7506A0, 06ER7756A0, 06ER7996A0, 06EM7506A0, 06E2565607EM 6E25506A0, 06E25656A0, 06E65656A0, 06E25756A0, 06E65756A0, 06E25996A0, 06E65996A0, 06E35656A0, 06E75656A0, 06E35756A0, 06E75756A0,6906A0,60906E75756A0,6909090905 ER150600, 06ER165600, 06ER175600, 06ER099600, 06EM150600, 06EA265600, 06EM175600, 06EM199600, 06EA250600602EF 75600, 06EF275600, 06EA299600, 06EA299600, 06ER750600 . 75600, 06E6275600, 06E2299600, 06E6299600, 06E3265600, 06E7265600, 06E3275600, 06E7275600, 06E7275600, 06E7275600, 06E32902

     

    kombaresarada carlyle

    Sharaxaada Alaabta

    • Socod-sare, oo si toos ah loo rogi karo bamka saliidda ayaa bixiya sifaynta saliidda-barakaca.
    • Nidaamka hawo-qaadista ee kiishku waxa uu barbardhigaa cadaadiska marka la bilaabayo waxaanu dammaanad qaadayaa in saliiddu ku soo noqoto sump.
    • Sump xad-dhaafka ah wuxuu ku hayaa saliid dheeri ah oo ku jira kiish si looga hortago in heerarku hoos uga dhaco qiyaasta saliidda ee badbaadada leh inta lagu jiro bilawga daadadku.
    • Biistoonada isku dhafan ayaa hoos u dhigaya nadiifinta dhululubada si ay u kordhiyaan awoodda kombarada iyo waxtarka
    • Furayaasha waxtarka sare leh waxay bixiyaan socodka qaboojiyaha oo kordhay iyo cadaadiska hoose.
    • Shidaalka cadaadiska saliida ee elektarooniga ah.
  • Koombasarrada weelka qaboojiyaha qaboojiyaha, kombaresarada sidaha 06DR241BCC06C0/79-66625-00

    Koombasarrada weelka qaboojiyaha qaboojiyaha, kombaresarada sidaha 06DR241BCC06C0/79-66625-00

    Horse Power 6.5 HP

    Compressor Tignoolajiyada Iskucelceliska ah

    Habka qaboojinta hawada la qaboojiyey

    Ma La Qaadan Karaa Haa

    Xawaaraha baabuurka 1750 RPM

    Midabka Buluugga ah

    Qaybta Number 79-66625-00

    CFM 41

    Saliida Castrol ee la ansixiyay

    Miisaanka 260 lb. (qalalan)

    Dalka Asal ahaan USA

    Carrier Brand

    Liiska CSA Haa

    Wareega/Hertz 50/60 Hz

    Wajiga Saddexaad

    Tirada Silinders 6

    Qaboojiyaha R134a

    Nooca Semi-Hermetic

    Voltage 400-460 VAC

  • Kombaresarka Carlyle 18-10134-23 102-795 18-10134-24

    Kombaresarka Carlyle 18-10134-23 102-795 18-10134-24

    kaydka, cusub

    Nambarka Qaabka:ZMD26KVE-TFD

    Miisaanka (Saliid): 42.9 kg (95 rodol)

    Saliid la ansixiyay: Uniqema Emkarate RL-32-3MAF

    Qiimaha Saliida: 1774 ml (60 wiqiyadood)

    Asal ahaan: USA

    Muaj Peev Xwm Ntau (BTU): 13500-64800

    Voltage @ Hz: 380/420 @ 50, 460 @ 60

    Tubada haa: R-134a

    Haddii ay jiraan, kombaresarada ayaa ah qaybta ugu muhiimsan ee nidaamka qaboojinta - xaqiiqaduna waxay tahay wadnaha hawlaha injineernimada ee Carrier uu fuliyo.Carrier ayaa naqshadeeya oo soo saara qaar ka mid ah kombaresarada ugu fiican ee loo isticmaalo hababka qaboojinta ee badaha.Si kastaba ha ahaatee, had iyo jeer waa suurtogal in qayb ka mid ah kombaresarada ay jabto oo u baahan tahay in la beddelo.Adeegga Arctic Reefer Service & Repair BV, waxaad joogtaa ciwaanka saxda ah si aad u soo iibsato qaybo kala duwan oo beddela kombaresarada qaadiyahaaga, sida gaasaska, daboolka gaasaska, valves adeegga, isgoysyada, iyo xitaa kombaresarada dhamaystiran.Ka hubi webshop-kayaga si aad u hesho qaybahan.

     

  • Carrier Carlyle Screw Compressor 06NW2209S7NA-A00 Compressor 104W Chiller
  • 40HP Qaboojiyaha qaboojiyaha

    40HP Qaboojiyaha qaboojiyaha

    Sumadda: Qaade
    Tusaalaha: 06EA299
    Awoodda: 40 hp
    Silinder: 6
    Awoodda (m3/h): 140.40 m3/h
    Qiimaha saliidda: 9 L
    Miisaanka saafiga ah: 236 kg
    Qaboojiyaha: R22

     

  • kombaresarada qaboojiyaha qaboojiyaha qaadaha qaboojiyaha kombaresarada 06E 06D liiska qiimaha

    kombaresarada qaboojiyaha qaboojiyaha qaadaha qaboojiyaha kombaresarada 06E 06D liiska qiimaha

    06er099/06ea299 Carlyle Compressor, 06ea250 06ea265 Semi-Hermetic Reciprocating Carrier 06e Compressor

    Carlyle 06D/E kombaresarada semi-hermetic waxay ku habboon yihiin qaboojiyaha ganacsiga, qaboojinta, qaboojinta habka, iyo qolalka deegaanka.Aad bay u dabacsan yihiin waxaana laga yaabaa in loo isticmaalo qaboojiyaha cusub ee HFC sida R-507, R-404A, R-407C iyo R-134a, marka lagu daro qaboojiyaha caadiga ah (R-12, R-22, iyo R) -502).Compressors-yada waxaa laga yaabaa in lagu shaqeeyo 50 ama 60 hertz waana UL, CE, CSA, iyo ISO 9002 waa la ansixiyay.

  • 120HP Carrier Screw Compressor 06NA2300S5NA-A00

    120HP Carrier Screw Compressor 06NA2300S5NA-A00

    Qaabka: 06NA2300 Taxanaha'

    HP: 120