Skrola i-ZR Series EMERSON Refrigeration Copeland compressor ZR94KCE-TFD-522
Imodeli | Ukusekelwa kwe-Volt :V/Isigaba | Susa indawo -umbhalo:cc/rev | Amandla Ehhashi:HP | Amandla okupholisa:Btu | Amandla Okufaka:W | Ama-Amps Omthwalo Olinganiselwe:A | Kukhiyiwe Irotha Amps:A | Inkokhelo Kawoyela Yokushintshwa: L |
I-ZR61KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 82.6 | 5 | 61880 | 5400 | 11 | 63 | 1.95 |
I-ZR72KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 98.1 | 6 | 73500 | 6250 | 13 | 75 | 1.77 |
I-ZR81KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 107.8 | 6.8 | 82000 | 6950 | 15 | 100 | 1.77 |
I-ZR84KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 113.6 | 7 | 85500 | 7300 | 15 | 100 | 2.51 |
I-ZR94KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 127.2 | 7.8 | 96500 | 8200 | 16 | 95 | 2.51 |
I-ZR108KC-TFD-522 | 380V/460V50-60Hz;3P | 142.9 | 9 | 109000 | 9200 | 17 | 114 | 3.25 |
I-ZR125KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 167.2 | 10 | 128000 | 10900 | 19 | 125 | 3.25 |
I-ZR144KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 190.9 | 12 | 146000 | 12300 | 22 | 125 | 3.25 |
I-ZR160KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 209.1 | 13 | 160000 | 13900 | 28 | 138 | 3.25 |
I-ZR190KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 249.2 | 16 | 190000 | 16800 | 34 | 173 | 3.25 |
ZR250KC-TWD-522 | 380V/460V50Hz/60Hz;3P | 325.2 | 20 | 249900 | 21700 | 30 | 225 | 4.67 |
I-ZR310KC-TWD-522 | 380V/460V50Hz/60Hz;3P | 410.6 | 25 | 306000 | 27100 | 38 | 272 | 6.80 |
I-ZR380KC-TWD-522 | 380V/460V50Hz/60Hz;3P | 502.7 | 32 | 379000 | 32700 | 45 | 310 | 6.30 |
I-Compressor Yekusasa
Ikusasa le-HVACR ligcwele ukungaqiniseki: imithetho emisha, imikhiqizo emisha namaqiniso amasha.Ukuthuthukisa i-HVAC nezinhlelo zesiqandisi ezihlangabezana nokusebenza kahle okusha nemithetho yesiqandisi kungaletha isethi entsha yezinselele eziyinkimbinkimbi.Ubuchwepheshe bethu bokuskrola besizukulwane esilandelayo se-Copeland buklanyelwe ukusebenza kahle okuphezulu kanye nohlu olugcwele lweziqandisi ze-GWP eziphansi futhi zifika ziphelele nezici ezihlakaniphile ezifana ne-plug-and-play electronics ukuze unikeze ukusebenza nokuvumelana nezimo okudingayo ukuze uklame uhlelo olulungele ukulawula.Ngaphandle kwama-compressor ethu esizukulwane esilandelayo se-Copeland ahlala enhliziyweni ye-HVAC nezinhlelo zesiqandisi abanikazi bezindlu, amabhizinisi nezimboni abathembele kuzo, ubuchwepheshe bethu obuhamba phambili embonini kanye nezinhlelo zokuqeqesha zingakusiza unqume ukuthi izinguquko ezizayo zisho ukuthini ebhizinisini lakho kuyilapho zikusiza ukuthi uthole. lungiselela izinselele zakusasa namuhla.
Isebenza kanjani i-scroll compressor?
Ama-compressor we-Copeland scroll asebenza ngomqulu owodwa ozungezayo endleleni echazwe umqulu ogxilile ofanayo.Umqulu ogxilile unamathiselwe emzimbeni we-compressor ngenkathi umqulu ozungezayo uhlanganiswe ne-crankshaft.Ukunyakaza okuzungezayo kudala uchungechunge lwamaphakethe egesi ahamba phakathi kwemiqulu emibili.Engxenyeni engaphandle yemiqulu, amaphakethe adonsa igesi bese ayihambisa phakathi nendawo yomqulu lapho ekhishwa khona.Njengoba igesi ingena phakathi nendawo yokuskrola, izinga lokushisa nokucindezela kuyakhuphuka kuye kumfutho wokukhipha ofunekayo.