I-compressor ye-Copeland

  • I-1020795 I-Thermo king compressors ZMD18KVE-TFD-275, i-compressor ye-copeland yesiqandisi

    I-1020795 I-Thermo king compressors ZMD18KVE-TFD-275, i-compressor ye-copeland yesiqandisi

    I-Thermo King idizayina futhi izakhele awabo ama-compressor aqondene ngqo nezidingo ezidlulele zezinhlelo zokulawula izinga lokushisa zamaloli ne-trailer.Ama-compressor ethu akhelwe ukuthi ahlale futhi athuthukiswa ngokuqhubekayo ukuze enze ubulungiswa ezidingweni eziphezulu zamakhasimende.

    Ama-compressor wangempela we-Thermo King athuthukiswa amaqembu azinikele onjiniyela be-Thermo King futhi ahlolwe kakhulu ezikhungweni ze-R&D ezisezingeni eliphezulu ukuze asebenze kahle nempilo ende ukuze akugcine usendleleni isikhathi eside.

    Izici Eziyinhloko

    • Ukusebenza kahle okuphezulu namandla amakhulu
    • Umsindo omncane nokudlidliza
    • Ukunakekelwa okuncane (87% izingxenye ezihambayo ezimbalwa)
    • I-E nickel-plated Oldham coupling yokwethembeka okukhulu

    I-MONDEL NO: ZMD18KVE-TFD-275

    Ingxenye #:102-0795

    1020795

     

  • I-Thermo King Compressors ZMD18KVE-TFD-977, i-Thermo King Compressors yesiqandisi, izingxenye ze-reefer

    I-Thermo King Compressors ZMD18KVE-TFD-977, i-Thermo King Compressors yesiqandisi, izingxenye ze-reefer

    I-thermo King compressor ZMD18KVE-TFD-977 iyi-compressor esebenza kahle kakhulu, ethembekile esetshenziswa kumayunithi esiqandisi eklanyelwe ukuthutha impahla ezwela izinga lokushisa ezitsheni ze-reefer.Le compressor isebenza ngomthamo omncane ongu-18,000 BTU/H futhi yakhelwe ngokukhethekile ukusebenza ngesiqandisi esingu-R-404A.I-compressor ye-ZMD18KVE ifaka idizayini yokuskrola ehlinzeka ngokusebenza okungaguquki kokupholisa futhi yakhelwe ukusebenza ngaphansi kwezimo zemvelo ezinzima.Ezinye zezingxenye ezibalulekile ongazidinga ku-Thermo King compressor ZMD18KVE zifaka izihlungi zikawoyela, izihlungi zokumunca, ama-gaskets, namabhande okushayela.Ukwengeza, ungase futhi udinge izingxenye zikagesi nezinzwa zezinga likawoyela ukuze ugcine iyunithi yakho isebenza kahle.

    I-ZMD18KVE iyi-compressor yokuskrola evela ku-Thermo King eyenzelwe izinhlelo zokusebenza zesiqandisi kumayunithi we-reefer.Inokususwa okungu-51.8 m³/hr (305 CFM) ngesivinini esikhulu sokusebenza esingu-3,600 RPM.I-compressor inamandla amahhashi alinganiselwe angu-6Hp futhi isebenzisa isiqandisi esingu-R-404A.Yaziwa ngokusebenza kwayo okuphezulu, umsindo ophansi, nokusebenza kokudlidliza.I-compressor ye-ZMD18KVE ivamise ukusetshenziswa kumayunithi ayisiqandisi amancane kuya kwasayizi omaphakathi ukuze kuthuthwe futhi kugcinwe impahla ebolayo.

    I-Thermo King idizayina futhi izakhele awabo ama-compressor aqondene ngqo nezidingo ezidlulele zezinhlelo zokulawula izinga lokushisa zamaloli ne-trailer.Ama-compressor ethu akhelwe ukuthi ahlale futhi athuthukiswa ngokuqhubekayo ukuze enze ubulungiswa ezidingweni eziphezulu zamakhasimende.

    I-40-ft efrijiwe ye-thermo king compressor ZMD18KVE ZMD26KVE reefer reefer izingxenye zokupholisa iziqukathi zenkampani yenethiwekhi

    Ama-compressor wangempela we-Thermo King athuthukiswa amaqembu azinikele onjiniyela be-Thermo King futhi ahlolwe kakhulu ezikhungweni ze-R&D ezisezingeni eliphezulu ukuze asebenze kahle nempilo ende ukuze akugcine usendleleni isikhathi eside.

    I-thermo King compressor ZMD18KVE-TFD-977 Izici Ezibalulekile

    • Ukusebenza kahle okuphezulu namandla amakhulu
    • Umsindo omncane nokudlidliza
    • Ukunakekelwa okuncane (87% izingxenye ezihambayo ezimbalwa)
    • I-E nickel-plated Oldham coupling yokwethembeka okukhulu

     

    Ukucaciswa kwe-thermo King compressor ZMD18KVE-TFD-977

     

    1020795

     

  • I-Copeland skrola i-compressor yedijithali 6hp, 8hp, 12hp, ZPD61KCE ZPD72KCE ZPD122KCE

    I-Copeland skrola i-compressor yedijithali 6hp, 8hp, 12hp, ZPD61KCE ZPD72KCE ZPD122KCE

    I-Compressor ye-Copeland Scroll Digital inyusa ukusebenza kahle kwesistimu ye-HVAC ngokushintsha umthamo futhi inikeze ukonga amandla ngokufanisa ngokunembile okuphumayo kwe-compressor nezidingo zakho zokushisisa noma zokupholisa.Lobu buchwepheshe bufaneleka kumabhilidi noma amagumbi anemithwalo ehlukahlukene noma lapho izinga lokushisa eliqinile kanye nokulawulwa komswakama kuyadingeka.

    copeland digital compressor induduzo ukufanisa izidingo zakho

    I-Copeland scroll digital inikeza ukuguqulwa kwe-compressor kusuka kumaphesenti angu-10-100, okuvumela amasistimu okupholisa ukuthi alungise ngokuzenzakalelayo umthamo njengoba kudingeka kuyilapho kunciphisa ukusetshenziswa kwamandla.Lobu buchwepheshe bokuskrola busebenza kahle ngamaphesenti angama-30 kunezindlela ezivamile zokuguquguquka kwesistimu.

    Ikhithi yokuthuthukisa ifaka i-Emerson Commercial Comfort Controller entsha kanye nevalvu edingekayo, ikhoyili, i-thermistor, kanye neshubhu edingekayo ukuze kushintshwe i-compressor ephelele.

    I-copeland digital compressor ZPD, uchungechunge lwe-ZRD lusesitokweni.

    Indlela yokuhlanza ye-air conditioning yasendlini yeyunithi yesiqandisi se-copeland digital compressor - Izinyathelo zokuhlanza zesimo sezulu esimaphakathi sasekhaya
    1. Vula i-grille yokudonsa, ubambe izinkinobho ezimbili, bese uzidonsela phansi kancane ngesikhathi esifanayo
    2. Donsa ihhuku kusihlungi somoya ngokudayagonali uye phansi bese ukhipha okokuhlunga.
    3. Indlela yokuhlanza: Sebenzisa i-vacuum cleaner ukuze ususe uthuli, noma uhlanze ngamanzi noma ngamanzi afudumele.Uma kunothuli oluningi, sebenzisa ibhulashi elithambile elinama-bristled kanye nokuhlanza okungathathi hlangothi.Ngemva kokugeza, vuthulula amanzi bese uwomisa endaweni epholile.Khumbula ukuthi ungasebenzisi amanzi ashisayo angaphezu kuka-50 ℃ ukuhlanza ukuze ugweme ukushintsha kombala noma ukubola;Ungawomisi emlilweni njengoba isisefo singase sibambe umlilo.
    4. Isihlungi somoya kufanele sifakwe ngemva kokuhlanza.Lengisa isihlungi somoya engxenyeni ephumayo engxenyeni engenhla ye-grille yokumunca, bese usilungisa ku-grille yokumunca;Shelelisela isibambo se-convex ngemuva kwe-grille yokumunca ngaphakathi bese ufake isihlungi somoya ku-grille yokumunca.
    5. Vala i-grille yokumunca, ngokuphambene nesinyathelo soku-1, cindezela inkinobho yokusetha kabusha isignali yesihlungi kuphaneli yokulawula, futhi uphawu lwesikhumbuzi sokuhlanza umoya omaphakathi luzonyamalala.Uma kunothuli oluningi endaweni yokusebenza, isihlungi somoya kufanele sihlanzwe cishe kanye njalo ezinyangeni eziyisithupha.

     

    ukuthengiswa okuqondile kwemboni ye-copeland digital compressor, entsha sha

    Inombolo Yemodeli:I-ZPD122KCE-TFD-532

    Isisindo (Ngamafutha): 62KG

    Amafutha Agunyaziwe: COA 32E 200L

    Ukushaja Amafutha: 3.3L

    Okwangempela: Thailand

    Ukufuduka: 19.7m3/h

    copeland digital compressor amamodeli amaningi ayatholakala

    I-compressor yedijithali ye-copeland

     

  • I-Piston compressor, i-semi hermetic compressor, i-compressor ye-copeland ye-DM
  • Copeland HVAC compressors zonke izinombolo model, chiller compressors

    Copeland HVAC compressors zonke izinombolo model, chiller compressors

    Ukucaciswa komkhiqizo Amandla amancane emoto [HP]: 6 Ukususwa [m³/h]]: 87.5 Izinga lokucindezela komsindo : 77 Isisindo Esiphelele/Isamba [kg]: 50 Ishaja kawoyela [dm³]: 1.95 Ukunikezwa kwamandla [V/~/Hz]: 380-420/3/50Hz I-rotor yamanje evaliwe [A]: 62 Max.ukusebenza kwamanje [A]: 32 Ukumelana okuvunguzayo [Ω]]: 0.37 Ishaja kawoyela [dm³]: 1.95 Umbala : Ukupakisha Okumnyama: Ikesi lezinkuni noma I-Pallet MOQ: 1pcs Compressor Condition:New HS : 8414301400
  • I-Copeland Refrigeration scroll compressor ZP235KCE-TWD-450 380-420V 3-Phase R410A

    I-Copeland Refrigeration scroll compressor ZP235KCE-TWD-450 380-420V 3-Phase R410A

    Ukusebenza

    I-Evaporator Temp.(ºF) 45 45

    I-Condensing Temp.(ºF) 130 100

    Buyisela I-Gas Temp.(ºF) 65 65

    I-Liquid Temp.(ºF) 115 85

    Amandla (Btu/hr) 235000 290000

    Amandla (W): 21100 15400

    I-EER (Btu/Wh): 11.10 18.80

    Ukugeleza Kwenqwaba (Ibs/hr): 3460 3590

    Okwamanje (Amps): 30.60 23.60

  • I-Copeland R410a scroll ac compressor cooling system ZP137KCE-TFD-450 ZP137KCE-TFD-950 ZP137KCE-TFD-522

    I-Copeland R410a scroll ac compressor cooling system ZP137KCE-TFD-450 ZP137KCE-TFD-950 ZP137KCE-TFD-522

    Imodeli: ZP137KCE-TFD-450

    1 Izingcezu

    I-150 Piece/ Izingcezu Ngenyanga

    Guangzhou

    T/T MoneyGram Credit Card/i-Western Union

    izinsuku

  • Skrola i-ZR Series EMERSON Refrigeration Copeland compressor ZR94KCE-TFD-522

    Skrola i-ZR Series EMERSON Refrigeration Copeland compressor ZR94KCE-TFD-522

    Imodeli:I-ZR94KCE-TFD-522

    Igama Brand: Copeland
    Uhlobo:I-Compressor yesiqandisi
    I-MOQ: 1pcs
    Ngemva Kwesevisi Yewaranti:Ukusekelwa kobuchwepheshe bevidiyo
  • Ihlinzeka kabanzi nge-12HP copeland scroll air conditioner compressor ZR144KCE-TFD-522 ZR144KC-TFD-522

    Ihlinzeka kabanzi nge-12HP copeland scroll air conditioner compressor ZR144KCE-TFD-522 ZR144KC-TFD-522

    Eyethuimikhiqizo inenzuzo yokuklama okunengqondo, ikhwalithi ezinzile nejwayelekile, intengo engcono kakhulu kanye nempahla esheshayo.Ngokubanziisetshenziswa ku-air conditioning, isitoreji esibandayo, ekugcinweni okubandayo, kwisiqandisi sezokwelapha, ekushiseni, iyunithi yokujiya,I-HVACizimboni neminye imikhakha.ama-compressor okushisa aphezulu, aphakathi nendawo naphansi wonke ayatholakala.

  • I-Copeland Refrigerator Scroll Compressor tandem units, i-Copeland 5HP Refrigerator Scroll Compressor

    I-Copeland Refrigerator Scroll Compressor tandem units, i-Copeland 5HP Refrigerator Scroll Compressor

    AmaParamenters Omkhiqizo Imodeli ZR61KC-TFD-522 Amandla Ehhashi (HP) 5.1HP Voltage 380V-440V/3Ph/50HZ-60HZ Isiqandisi R22 Amandla Okupholisa(W) 14550W Amandla Okupholisa (Btu/h) 49h470 Btucc/Replacement Btucc 82.6 cc/Rev Input power (W) 4430W Current(A) 8.2A COP(w/w) 3.28w/w EER(Btu/Wh) 11.2Btu/Wh Net weight(kg) 36.1kg Ukupakisha Ikesi Lokhuni Ukuhluleka kokuvinjwa okungcolile kukhona okubangelwa ukungcola okweqile ohlelweni lwesiqandisi.Imithombo emikhulu ye...
  • I-Oilless Cold Room Scroll Compressor Refrigeration Compressor, i-copeland air conditioning compressors

    I-Oilless Cold Room Scroll Compressor Refrigeration Compressor, i-copeland air conditioning compressors

    5 kuya ku-40 Ton Copeland Scroll™ Compressors, copeland ZR,ZP,ZB,CR uchungechunge

    I-Copeland Compressors yama-Air Conditioners

    I-Copeland Scroll iziqhayisa ngomugqa obanzi kakhulu wama-compressor ahambisana namayunithi omoya.Ama-compressor e-Copeland asukela ku-1/3-60 HP, alungele kokubili izinhlelo zokusebenza zokuhlala nezokuhweba.

  • I-10HP Copeland ZR Scroll Compressors ZR125KCE-TFD-522

    I-10HP Copeland ZR Scroll Compressors ZR125KCE-TFD-522

    Imininingwane

    Ukuhambisana kwamafriji
    I-R-134a, R-22, R-407C
    Amandla kagesi :380-420 V ku-50 Hz, 460 V ku-60 Hz
    Imvamisa:50, 60 Hz
    Isigaba:3
    Amandla Okupholisa:27.00 kW
    Okokufaka Amandla:8.05 kW
    I-COP:3.35
    Ukufuduka:29.1 m³/h
    Ubukhulu Babonke / Isisindo Sesamba:285 x 264 x 533 mm (W x L x H) / 61.2 kg
    I-PS Ephansi/Ephezulu:20/32 ibha(g)
    Ubuningi Bokusebenza Kwamanje:19.6 A
    Amandla Omsindo:80dBA
    Uhlobo lwamafutha :I-POE