Samfura | Taimakon Volt:V/Mataki | Kaura -ment: cc/rev | Ƙarfin Doki: HP | Iyawar sanyaya: Btu | Ƙarfin shigarwa: W | Matsakaicin Load Amps: A | Kulle Rotor Amsa: A | Canjin Mai Canjin: L |
Saukewa: ZR61KC-TFD-522 | 380V/460V50Hz/60Hz; 3P | 82.6 | 5 | 61880 | 5400 | 11 | 63 | 1.95 |
Saukewa: ZR72KC-TFD-522 | 380V/460V50Hz/60Hz; 3P | 98.1 | 6 | 73500 | 6250 | 13 | 75 | 1.77 |
Saukewa: ZR81KC-TFD-522 | 380V/460V50Hz/60Hz; 3P | 107.8 | 6.8 | 82000 | 6950 | 15 | 100 | 1.77 |
Saukewa: ZR84KC-TFD-522 | 380V/460V50Hz/60Hz; 3P | 113.6 | 7 | 85500 | 7300 | 15 | 100 | 2.51 |
Saukewa: ZR94KC-TFD-522 | 380V/460V50Hz/60Hz; 3P | 127.2 | 7.8 | 96500 | 8200 | 16 | 95 | 2.51 |
Saukewa: ZR108KC-TFD-522 | 380V/460V50-60Hz; 3P | 142.9 | 9 | 109000 | 9200 | 17 | 114 | 3.25 |
Saukewa: ZR125KC-TFD-522 | 380V/460V50Hz/60Hz; 3P | 167.2 | 10 | 128000 | 10900 | 19 | 125 | 3.25 |
Saukewa: ZR144KC-TFD-522 | 380V/460V50Hz/60Hz; 3P | 190.9 | 12 | 146000 | 12300 | 22 | 125 | 3.25 |
Saukewa: ZR160KC-TFD-522 | 380V/460V50Hz/60Hz; 3P | 209.1 | 13 | 160000 | 13900 | 28 | 138 | 3.25 |
Saukewa: ZR190KC-TFD-522 | 380V/460V50Hz/60Hz; 3P | 249.2 | 16 | 190000 | 16800 | 34 | 173 | 3.25 |
Saukewa: ZR250KC-TWD-522 | 380V/460V50Hz/60Hz; 3P | 325.2 | 20 | 249900 | 21700 | 30 | 225 | 4.67 |
Saukewa: ZR310KC-TWD-522 | 380V/460V50Hz/60Hz; 3P | 410.6 | 25 | 306000 | 27100 | 38 | 272 | 6.80 |
Saukewa: ZR380KC-TWD-522 | 380V/460V50Hz/60Hz; 3P | 502.7 | 32 | 379000 | 32700 | 45 | 310 | 6.30 |
Compressor na gaba
Makomar HVACR tana cike da rashin tabbas: sabbin ka'idoji, sabbin samfura da sabbin abubuwa.Haɓaka tsarin HVAC da na'urorin firiji waɗanda ke saduwa da sabbin ingantattun ƙa'idodi da ƙa'idodi na sanyi na iya gabatar da sabbin ƙalubale masu rikitarwa.Fasahar gungurawa ta gaba-gen Copeland an ƙera ta don mafi girman inganci da cikakken kewayon ƙarancin GWP mai sanyi kuma ya zo cikakke tare da fasali masu wayo kamar na'urorin toshe-da-wasa don samar da aiki da sassauƙar da kuke buƙata don tsara tsarin tsara tsari.Bayan mu na gaba-gen Copeland compressors waɗanda ke zaune a zuciyar HVAC da tsarin sanyi wanda masu gida, kasuwanci da masana'antu suka dogara da su, ƙwarewar masana'antarmu da shirye-shiryen horarwa na iya taimaka muku sanin menene canje-canje masu zuwa ke nufi ga kasuwancin ku yayin taimaka muku samun. shirya don kalubalen gobe a yau.
Ta yaya kwampreshin gungura yake aiki?
Kwamfutocin Copeland na gungurawa suna aiki tare da gungurawa guda ɗaya da ke kewayawa a hanyar da aka ayyana ta madaidaiciyar gungurawa.Madaidaicin gungura yana haɗe zuwa jikin kwampreso yayin da gungurawar kewayawa ke haɗe zuwa crankshaft.Motsin kewayawa yana haifar da jeri na aljihun gas da ke tafiya tsakanin littattafan biyu.A gefen littattafan naɗaɗɗen, aljihunan sun zana iskar gas sannan su matsar da shi zuwa tsakiyar littafin inda aka fitar da shi.Yayin da iskar gas ke motsawa zuwa tsakiyar gungura, zafin jiki da matsa lamba suna ƙaruwa zuwa matsin fitarwa da ake so.