Gulung ZR Series EMERSON Refrigeration Copeland compressor ZR94KCE-TFD-522
Modél | rojongan volt: V / Fase | Mindahkeun -ment:cc/rev | Daya kuda: HP | Kapasitas cooling: Btu | Daya Input: W | Dipeunteun Beban Amps:A | Kakonci Rotor Ampere: A | Panggantian Oli Biaya: L |
ZR61KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 82.6 | 5 | 61880 | 5400 | 11 | 63 | 1.95 |
ZR72KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 98.1 | 6 | 73500 | 6250 | 13 | 75 | 1.77 |
ZR81KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 107.8 | 6.8 | 82000 | 6950 | 15 | 100 | 1.77 |
ZR84KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 113.6 | 7 | 85500 | 7300 | 15 | 100 | 2.51 |
ZR94KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 127.2 | 7.8 | 96500 | 8200 | 16 | 95 | 2.51 |
ZR108KC-TFD-522 | 380V/460V50-60Hz;3P | 142.9 | 9 | 109000 | 9200 | 17 | 114 | 3.25 |
ZR125KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 167.2 | 10 | 128000 | 10900 | 19 | 125 | 3.25 |
ZR144KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 190.9 | 12 | 146000 | 12300 | 22 | 125 | 3.25 |
ZR160KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 209.1 | 13 | 160000 | 13900 | 28 | 138 | 3.25 |
ZR190KC-TFD-522 | 380V/460V50Hz/60Hz;3P | 249.2 | 16 | 190000 | 16800 | 34 | 173 | 3.25 |
ZR250KC-TWD-522 | 380V/460V50Hz/60Hz;3P | 325.2 | 20 | 249900 | 21700 | 30 | 225 | 4.67 |
ZR310KC-TWD-522 | 380V/460V50Hz/60Hz;3P | 410.6 | 25 | 306000 | 27100 | 38 | 272 | 6.80 |
ZR380KC-TWD-522 | 380V/460V50Hz/60Hz;3P | 502.7 | 32 | 379000 | 32700 | 45 | 310 | 6.30 |
Compressor of Future
Masa depan HVACR pinuh ku kateupastian: peraturan anyar, produk anyar sareng kanyataan anyar.Ngembangkeun sistem HVAC sareng refrigerasi anu nyumponan efisiensi anyar sareng peraturan refrigeran tiasa nampilkeun sakumpulan tantangan anu kompleks.Téknologi gulung Copeland generasi saterusna urang geus dirancang pikeun efisiensi maksimum sarta rentang pinuh ku refrigerants low-GWP tur datang kumplit jeung fitur pinter kawas éléktronik plug-na-muter pikeun nyadiakeun kinerja sarta kalenturan nu peryogi pikeun rarancang sistem-siap pangaturan.Saluareun kompresor Copeland generasi salajengna urang anu cicing di jantung HVAC sareng sistem kulkas anu digantungkeun ku pamilik bumi, usaha sareng industri, program kaahlian sareng pelatihan anu ngarah di industri urang tiasa ngabantosan anjeun nangtukeun naon hartosna parobihan anu bakal datang pikeun bisnis anjeun bari ngabantosan anjeun. nyiapkeun tantangan énjing dinten ayeuna.
Kumaha compressor ngagugulung tiasa dianggo?
Kompresor ngagugulung Copeland tiasa dianggo sareng hiji gulungan anu ngorbit dina jalur anu ditetepkeun ku gulungan tetep anu cocog.Gulungan tetep napel kana awak compressor bari ngagugulung ngorbit ieu gandeng kana crankshaft nu.Gerak ngorbit nyiptakeun runtuyan kantong gas ngarambat antara dua gulungan.Dina bagian luar gulungan, kantong narik gas lajeng mindahkeun ka tengah gulungan dimana eta discharged.Salaku gas ngalir kana puseur ngagugulung urang, hawa sarta tekanan naek kana tekanan ngurangan nu dipikahoyong.