Ayini amandla ehhashi lesiqandisi sikagesi seziqukathi eziqandisiwe?

Amandla esiqandisi eziqukathi eziqandisiwe ayafana, kodwa kuyadingeka ukuhlukanisa phakathi kokugcinwa kokusha nokubanda.Amandla esiqandisi angaba ngu-11kw lapho ukulondolozwa kokusha kungaphezu kwamadigri angu-0, futhi cishe u-7kw lapho iqhwa lingu-18 degrees.
Isiqandisi sikagesi sesitsha esiqandisiwe esingu-40
30P compressor, 16 square cable.
40 ifriji ephezulu: ubukhulu bangaphakathi bungu-11.62m × 2.29m × 2.50m/isisindo esijwayelekile sokusatshalaliswa kwempahla ngu-22t/ivolumu ingu-67m3.

Izinhlobo ze-Reefer compressors carrier, izinhlobo ze-thermo king, izinhlobo ze-copeland zithandwa kakhulu.
Kunezinhlobo ezimbili zeziqukathi eziqandisiwe: zangaphandle nezangaphakathi.Izinga lokushisa lingashintshwa ukusuka - 60 ℃ kuya +30 ℃.
Isitsha esakhelwe ngaphakathi singakwazi ukuqala isiqandisi ngokuthanda ngesikhathi sokuthutha ukuze sigcine isitsha ekushiseni okucacisiwe;Uhlobo lwangaphandle kufanele luthembele esiqandisini esifakwe ezimotweni ezikhethekile zamabhokisi, imikhumbi kanye neziteshi ezikhethekile zasegcekeni lokugcina ukuze kuphole.Leli bhokisi lifanele ukuthutha ibhotela, ushokoledi, izinhlanzi eziqandisiwe, ubisi olujiyile, imajarini, njll.
Lapho iziqukathi eziqandisiwe zisetshenziselwa ukuthutha impahla eqandisiwe, izinga lokushisa akufanele libe ngaphezu kuka-18 ℃.

I-compressor ye-marine compressor carrier compressor 06DR241BCC06C0 isetshenziswa kabanzi .

Ngokuvamile, isilinganiso sokupholisa esimaphakathi sesiqukathi esifakwe efrijini singu-31.3 ℃/h (isitsha esingenalutho);Kodwa-ke, ngemva kokulayisha, ngenxa yomthamo omkhulu wokushisa wezimpahla, isivinini sokupholisa sizoncishiswa kakhulu, ngezinye izikhathi kuthatha i-15-16h ukuhlangabezana nezidingo zokushisa ezibekiwe.Uma izinga lokushisa elingenayo liphezulu, kuthatha i-2-3d ukufinyelela izinga lokushisa elibekiwe.ama-conpressor wesitsha zonke izinombolo zemodeli ziyatholakala.
Ijubane lokukhuphuka nokuwa kwezinga lokushisa esitsheni esiqandisiwe lihlobene nezimpahla ezilayishwe esitsheni.Lapho izinga lokushisa lifinyelela ebangeni elimisiwe - 18 ℃± 3 ℃, izinga lokushisa esitsheni kufanele ligcinwe lizinzile.Kodwa-ke, ifomula elandelayo ye-empirical ingasetshenziswa njengenani elijwayelekile lokubala ukunyuka kwezinga lokushisa lapho isiqandisi singenasiqandisi.
1. Ukupholisa impahla (ngaphandle kokungena komoya) 0.0054 * (tw tn) ℃/h
2. Impahla eqandisiwe 0.0067 * (tw tn) ℃/h
Lapho i-tw ne-tn kuyizinga lokushisa langaphandle kanye nezinga lokushisa ebhokisini ℃ ngokulandelanayo.

Reefer compressors, Marine compressors, 40ft esitsheni compressors esitokweni.

 


Isikhathi sokuthumela: Dec-05-2022