6,5 HP nesēja kompresora konteinera kompresors 06DR241BCC06C0
6,5 HP nesēja kompresora konteinera kompresors 06DR241BCC06C0
Nesēja daļēji hermētisks virzuļu kompresors ar 06D un 06Eseries, to ļoti populāri izmanto jebkurai augstas temperatūras un zemas temperatūras videi:
1. Plaši izmanto komerciālā aukstumaģenta, gaisa kondicionētāja, tehnikas dzesēšanas un vides kabīnē.
2. Ar augstu elastību var ne tikai izmantot aukstumnesēju R-22, R12, R-501, bet arī der R404a, R134a, R507
3. Tas ir piemērots gan 50HZ, gan 60HZ spriegumam
Tehniskie dati
MODELIS | HP | CFM pie 1750 apgr./min | SŪKŠANAS TEMPERATŪRAS DARBĪBAS (GRĀDI F) | CYL NO | urbumi (collas) | STŪKS (COLLAS) | EĻĻAS LĀDE (PINTS) | |||||
R502/R404A/R507 | R12/R134a | R22 | ||||||||||
MIN | MAX | MIN | MAX | MIN | MAX | |||||||
06DR109 | 2.0 | 8.7 | -40 | 0 | -10 | 55 | -35 | 0 | 2 | 2.00 | 1-3/8 | 3.00 |
06DM808 | 3.0 | 8.0 | 0 | 50 | - | - | 0 | 55 | 2 | 2.00 | 1-1/4 | 3.00 |
06DR013 | 3.0 | 13.1 | -40 | 0 | -10 | 55 | -35 | 0 | 4 | 2.00 | 1 | 4.50 |
06DM313 | 5.0 | 13.1 | 0 | 50 | - | - | 0 | 55 | 4 | 2.00 | 1 | 4.50 |
06DR316 | 5.0 | 15.9 | -40 | 25 | -10 | 55 | -35 | 25 | 4 | 2.00 | 1-1/4 | 4.50 |
06DM316 | 5.0 | 15.9 | 0 | 25 | - | - | 0 | 45 | 4 | 2.00 | 1-1/4 | 4.50 |
06DR718 | 5.0 | 18.3 | -40 | 0 | -10 | 55 | -35 | 0 | 4 | 2.00 | 1-7/16 | 5.50 |
06DA818 | 6.5 | 18.3 | 0 | 50 | - | - | 0 | 55 | 4 | 2.00 | 1-7/16 | 5.50 |
06DR820 | 6.5 | 20.0 | -40 | 40 | -10 | 55 | -35 | 45 | 4 | 2.00 | 1-9/16 | 5.50 |
06DR724 | 6.5 | 23.9 | -40 | 25 | -10 | 55 | -35 | 45 | 6 | 2.00 | 1-1/4 | 8.00 |
06DR725 | 6.5 | 23.9 | -40 | 25 | -10 | 55 | -35 | 45 | 6 | 2.00 | 1-1/4 | 8.00 |
06DA825 | 7.5 | 23.9 | 0 | 50 | - | - | 0 | 55 | 6 | 2.00 | 1-1/4 | 8.00 |
06DA824 | 7.5 | 23.9 | 0 | 50 | - | - | 0 | 55 | 6 | 2.00 | 1-1/4 | 8.00 |
06DR228 | 7.5 | 28.0 | -40 | 25 | -10 | 55 | -35 | 45 | 6 | 2.00 | 1-15/32 | 8.00 |
06DA328 | 10.0 | 28.0 | 0 | 50 | - | - | 0 | 55 | 6 | 2.00 | 1-15/32 | 8.00 |
06DR337 | 10.0 | 37.1 | -40 | 25 | -10 | 55 | -35 | 45 | 6 | 2.00 | 1-15/16 | 8.00 |
06DM337 | 10.0 | 37.1 | 0 | 25 | - | - | 0 | 45 | 6 | 2.00 | 1-15/16 | 8.00 |
06DA537 | 15.0 | 37.1 | 0 | 50 | - | - | 0 | 55 | 6 | 2.00 | 1-15/16 | 8.00 |
06DR541 | 15.0 | 41.0 | -40 | 25 | -10 | 55 | -35 | 25 | 6 | 2.00 | 2.15 | 8.00 |
06ER450 | 15.0 | 50.3 | -40 | 0 | - | - | -35 | 0 | 4 | 2-11/16 | 2-3/16 | 14.00 |
06EM450 | 15.0 | 50.3 | 0 | 25 | -10 | 55 | 0 | 45 | 4 | 2-11/16 | 2-3/16 | 14.00 |
06EA550 | 20.0 | 50.3 | 0 | 50 | - | - | 0 | 50 | 4 | 2-11/16 | 2-3/16 | 14.00 |
06ER465 | 20.0 | 68.3 | -40 | 0 | - | - | -35 | 0 | 6 | 2-11/16 | 1-63/64 | 19.00 |
06EA565 | 25.0 | 68.3 | 0 | 50 | -10 | 55 | 0 | 50 | 6 | 2-11/16 | 1-63/64 | 19.00 |
06ER475 | 20.0 | 75.4 | -40 | 0 | - | - | -35 | 0 | 6 | 2-11/16 | 2-3/16 | 19.00 |
06EM475 | 25.0 | 75.4 | 0 | 40 | -10 | 55 | 0 | 45 | 6 | 2-11/16 | 2-3/16 | 19.00 |
06EA575 | 30.0 | 75.4 | 0 | 50 | - | - | 0 | 50 | 6 | 2-11/16 | 2-3/16 | 19.00 |
06ER399 | 30.0 | 99,0 | -40 | 0 | - | - | -35 | 0 | 6 | 2-11/16 | 2-7/8 | 19.00 |
06EM499 | 35.0 | 99,0 | 0 | 40 | -10 | 55 | 0 | 45 | 6 | 2-11/16 | 2-7/8 | 19.00 |
06EA599 | 40.0 | 99,0 | 0 | 50 | - | - | 0 | 50 | 6 | 2-11/16 | 2-7/8 | 19.00 |