Compressor container compressor 6.5HP 06DR241BCC06C0

Tuairisgeul goirid:

Dath: Gorm
Voltage: 400V / 3pH
Tricead: 50 Hz
Cumhachd eich: 6.5HP
Comas: 140.4m3/U
NW: 130.5 kg

Mion-fhiosrachadh toraidh

Bathar Tags

Compressor container compressor 6.5HP 06DR241BCC06C0
Compressor piston leth-hermetic giùlan le 06D & 06Eseries, tha e air a chleachdadh gu mòr airson àrainneachd àrd-teòthachd & teòthachd ìosal:
1.Widely cleachdadh ann an malairteach fuaradair, adhair-conditioner, fuarachadh technics agus àrainneachd cabin.
2.Le sùbailteachd àrd, chan e a-mhàin gu bheil e comasach inneal-fuarachaidh R-22, R12, R-501 a chleachdadh, ach cuideachd uidheamachadh R404a, R134a, R507
3.It freagarrach airson an dà chuid bholtaids 50HZ agus 60HZ

Dàta Teicnigeach

MODEL HP CFM aig 1750 rpm Raon Teòthachd suidse (ceumannan F) CYL NO BORES (Inches) STRòc (Inches) Cìs Ola (PINTS)
R502/R404A/R507 R12/R134a R22
MIN MAX MIN MAX MIN MAX
06DR109 2.0 8.7 -40 0 -10 55 -35 0 2 2.00 1-3/8 3.00
06DM808 3.0 8.0 0 50 - - 0 55 2 2.00 1-1/4 3.00
06DR013 3.0 13.1 -40 0 -10 55 -35 0 4 2.00 1 4.50
06DM313 5.0 13.1 0 50 - - 0 55 4 2.00 1 4.50
06DR316 5.0 15.9 -40 25 -10 55 -35 25 4 2.00 1-1/4 4.50
06DM316 5.0 15.9 0 25 - - 0 45 4 2.00 1-1/4 4.50
06DR718 5.0 18.3 -40 0 -10 55 -35 0 4 2.00 1-7/16 5.50
06DA818 6.5 18.3 0 50 - - 0 55 4 2.00 1-7/16 5.50
06DR820 6.5 20.0 -40 40 -10 55 -35 45 4 2.00 1-9/16 5.50
06DR724 6.5 23.9 -40 25 -10 55 -35 45 6 2.00 1-1/4 8.00
06DR725 6.5 23.9 -40 25 -10 55 -35 45 6 2.00 1-1/4 8.00
06DA825 7.5 23.9 0 50 - - 0 55 6 2.00 1-1/4 8.00
06DA824 7.5 23.9 0 50 - - 0 55 6 2.00 1-1/4 8.00
06DR228 7.5 28.0 -40 25 -10 55 -35 45 6 2.00 1-15/32 8.00
06DA328 10.0 28.0 0 50 - - 0 55 6 2.00 1-15/32 8.00
06DR337 10.0 37.1 -40 25 -10 55 -35 45 6 2.00 1-15/16 8.00
06DM337 10.0 37.1 0 25 - - 0 45 6 2.00 1-15/16 8.00
06DA537 15.0 37.1 0 50 - - 0 55 6 2.00 1-15/16 8.00
06DR541 15.0 41.0 -40 25 -10 55 -35 25 6 2.00 2.15 8.00
06ER450 15.0 50.3 -40 0 - - -35 0 4 2-11/16 2-3/16 14.00
06EM450 15.0 50.3 0 25 -10 55 0 45 4 2-11/16 2-3/16 14.00
06EA550 20.0 50.3 0 50 - - 0 50 4 2-11/16 2-3/16 14.00
06ER465 20.0 68.3 -40 0 - - -35 0 6 2-11/16 1-63/64 19.00
06EA565 25.0 68.3 0 50 -10 55 0 50 6 2-11/16 1-63/64 19.00
06ER475 20.0 75.4 -40 0 - - -35 0 6 2-11/16 2-3/16 19.00
06EM475 25.0 75.4 0 40 -10 55 0 45 6 2-11/16 2-3/16 19.00
06EA575 30.0 75.4 0 50 - - 0 50 6 2-11/16 2-3/16 19.00
06ER399 30.0 99.0 -40 0 - - -35 0 6 2-11/16 2-7/8 19.00
06EM499 35.0 99.0 0 40 -10 55 0 45 6 2-11/16 2-7/8 19.00
06 EA599 40.0 99.0 0 50 - - 0 50 6 2-11/16 2-7/8 19.00