6.5HP cab kuj compressor thawv compressor 06DR241BCC06C0

Lus piav qhia luv luv:

Xim: Xiav
Voltage: 400V/3 pH
Ntau zaus: 50 Hz
Nees Lub Zog: 6.5hp ib
Muaj peev xwm: 140.4 m3 / H
NW: 130.5 kg ib

Product Detail

Khoom cim npe

6.5HP cab kuj compressor thawv compressor 06DR241BCC06C0
Carrier semi-hermetic Piston compressor nrog 06D & 06Eseries, nws nrov heev siv rau txhua qhov kub thiab txias ib puag ncig:
1.Widely siv nyob rau hauv kev lag luam refrigerant, cua txias, technics chilling thiab ib puag ncig cabin.
2.Nrog siab yooj, nws tsis tsuas yog siv tau cov tub yees R-22, R12, R-501, tab sis kuj haum R404a, R134a, R507
3.Nws haum rau ob qho tib si 50HZ thiab 60HZ voltage

Cov ntaub ntawv technical

Qauv HP CFM @ 1750 RPM SUCTION TEMPERATURE RANGE (DEGREES F) CYL NO BORES (INCHES) STROKE (INCHES) PIB (PINTS)
R502/R404A/R507 R12/R134a R22
MIN MAX MIN MAX MIN MAX
06 DR 109 2.0 8.7 ib -40 0 -10 55 -35 0 2 2.00 Nws 1-3/8 3.00 Nws
06 tx808 3.0 8.0 ib 0 50 - - 0 55 2 2.00 Nws 1-1/4 3.00 Nws
06 DR 013 3.0 13.1 -40 0 -10 55 -35 0 4 2.00 Nws 1 4.50 Nws
06 tx313 5.0 13.1 0 50 - - 0 55 4 2.00 Nws 1 4.50 Nws
06 TSI 316 5.0 15.9 ib -40 25 -10 55 -35 25 4 2.00 Nws 1-1/4 4.50 Nws
06 tx316 5.0 15.9 ib 0 25 - - 0 45 4 2.00 Nws 1-1/4 4.50 Nws
06 tx718 5.0 18.3 ib -40 0 -10 55 -35 0 4 2.00 Nws 1-7/16 5.50 Nws
06 tx818 6.5 18.3 ib 0 50 - - 0 55 4 2.00 Nws 1-7/16 5.50 Nws
06 tx820 6.5 20.0 Nws -40 40 -10 55 -35 45 4 2.00 Nws 1-9/16 5.50 Nws
06 TSI 724 6.5 23.9 Nws -40 25 -10 55 -35 45 6 2.00 Nws 1-1/4 8.00 Nws
06 tx725 6.5 23.9 Nws -40 25 -10 55 -35 45 6 2.00 Nws 1-1/4 8.00 Nws
06 tx825 7.5 23.9 Nws 0 50 - - 0 55 6 2.00 Nws 1-1/4 8.00 Nws
06 tx824 7.5 23.9 Nws 0 50 - - 0 55 6 2.00 Nws 1-1/4 8.00 Nws
06 AWV 228 7.5 28.0 Nws -40 25 -10 55 -35 45 6 2.00 Nws 1-15/32 ib 8.00 Nws
06 tx328 10.0 28.0 Nws 0 50 - - 0 55 6 2.00 Nws 1-15/32 ib 8.00 Nws
06, HWV 337 10.0 37.1 ib -40 25 -10 55 -35 45 6 2.00 Nws 1-15/16 8.00 Nws
06 tx337 10.0 37.1 ib 0 25 - - 0 45 6 2.00 Nws 1-15/16 8.00 Nws
06 tx537 15.0 Nws 37.1 ib 0 50 - - 0 55 6 2.00 Nws 1-15/16 8.00 Nws
06 tx541 15.0 Nws 41.0 Nws -40 25 -10 55 -35 25 6 2.00 Nws 2.15 8.00 Nws
06 r450 15.0 Nws 50.3 -40 0 - - -35 0 4 2-11/16 2-3/16 14.00 Nws
06 e450 15.0 Nws 50.3 0 25 -10 55 0 45 4 2-11/16 2-3/16 14.00 Nws
06 tx550 20.0 Nws 50.3 0 50 - - 0 50 4 2-11/16 2-3/16 14.00 Nws
06 tx465 20.0 Nws 68.3 ib -40 0 - - -35 0 6 2-11/16 1-63/64 ib 19.00 Nws
06 tx565 25.0 Nws 68.3 ib 0 50 -10 55 0 50 6 2-11/16 1-63/64 ib 19.00 Nws
06 tx475 20.0 Nws 75.4 ib -40 0 - - -35 0 6 2-11/16 2-3/16 19.00 Nws
06 y475 25.0 Nws 75.4 ib 0 40 -10 55 0 45 6 2-11/16 2-3/16 19.00 Nws
06 tx575 30.0 Nws 75.4 ib 0 50 - - 0 50 6 2-11/16 2-3/16 19.00 Nws
06 tx399 30.0 Nws 99.0 ua -40 0 - - -35 0 6 2-11/16 2-7/8 19.00 Nws
06 y499 35.0 Nws 99.0 ua 0 40 -10 55 0 45 6 2-11/16 2-7/8 19.00 Nws
06 tx599 40.0 Nws 99.0 ua 0 50 - - 0 50 6 2-11/16 2-7/8 19.00 Nws

  • Yav dhau los:
  • Tom ntej:

  • Sau koj cov lus ntawm no thiab xa tuaj rau peb