Carlyle compressor

  • RSH105GD01 RSH105GR01

    RSH105GD01 RSH105GR01

    Compressor mai ɗaukar hoto, sashi na NO.18-10134-23 kwampreso gungura dako sassa don sakefe

    Saukewa: RSH105GD01
    ikon doki: 10 hp
    Tushen wutar lantarki: 440-460V/3/60Hz
    400v/3/50hz
    LRA:80
    firiji: r134a/r407c/r404a
    Menene ya kamata a kula da shi a cikin rufin ajiya na sanyi da kuma kiyaye makamashi?Mai ɗaukar r134a gungura kwampreshin RSH105GD01
    Saboda halaye na sama na gine-ginen ajiyar sanyi, baya ga tsauraran rufi, rufewa, dorewa, da juriya na sanyi a cikin ƙira da gini don tabbatar da ingancin gini, a cikin amfani da gudanarwa na yau da kullun, sarrafa kimiyya da samar da lafiya ya kamata kuma a aiwatar da su bisa ga halaye na ajiyar sanyi don tsawaita rayuwar sabis, rage farashin samarwa, adana farashin kulawa, da haɓaka haɓakar kasuwancin kasuwanci.Ajiye sanyi gini ne na musamman da ake amfani da shi don daskare abinci da sanyaya, da kuma kula da ƙarancin zafi.Ana amfani da compressors masu ɗaukar kaya akan jiragen ruwa, kuma ana girka magoya bayan axial masu kauri akan benaye, bango, da rufin ɗakin ajiyar.
    Saukewa: RSH105GD01
    Compressors masu ɗaukar nauyi suna haifar da zafi, da kuma magance matsalolin damfara.Daga hangen nesa na kiyaye makamashi, wajibi ne don rage girman lokacin farawa da adadin raka'a, Duk da haka, a cikin ainihin kayan 'ya'yan itace da kayan lambu, hanyar aiki wanda ke da tattalin arziki da ingancin samfurin shine: lokacin shigar da sito, duk kwararar axial. ana kunna magoya baya, kuma ana amfani da na'urorin damfara mai ɗaukar hoto.Bayan yanayin zafi ya daidaita, an rage adadin raka'a da aka buɗe, kuma ana sanya tsauraran buƙatun zafin jiki akan nau'ikan ajiya.Domin tabbatar da daidaiton zafin jiki tsakanin manyan sassa da ƙananan sassa, 1-2 magoya bayan kwararar axial har yanzu ana ci gaba da aiki lokacin da aka dakatar da firiji da samar da ruwa.Ana ƙididdige Layer mai tabbatar da danshi da rufin rufi na kwampreso gabaɗaya ta amfani da ingantattun hanyoyin gwajin rayuwa don rayuwar aiki na kwampreso.
    Saukewa: RSH105GD01
    Hanyoyin da aka saba amfani da su sun haɗa da gwajin lalacewa na 68t, 1000h, 2000h ko ma gwajin rayuwa mai tsawo, 2000 ', da gwajin rayuwar sa'a, wanda kuma zai iya tantance dacewa da kayan daban-daban.

     

  • 40HP Carlyle Compressors 06EA299600 don Na'urar sanyaya iska

    40HP Carlyle Compressors 06EA299600 don Na'urar sanyaya iska

    Brand : Mai ɗauka
    Saukewa: 06EA299600
    Wutar lantarki: 40 hp
    Silinda: 6
    Iya aiki (m3/h): 140.40 m3/h
    Farashin mai: 9L
    Net nauyi: 236 kg
    Saukewa: R22

  • Cold Room/Chiller Compressor carlyle 06E Mai dakon Firiji 06EA265,06EA275,06EA565

    Cold Room/Chiller Compressor carlyle 06E Mai dakon Firiji 06EA265,06EA275,06EA565

    Samfuran Akwai

    06ER4506A0, 06ER4656A0, 06ER4756A0, 06ER4756A0, 06ER4756A0, 06EM4506A0, 06EA5656A0, 06EM4756A0, 06EM4996A0, 06EA5506A0, 6EF 06EA5756A0, 06EF5756A0, 06EA5996A0, 06EF5996A0, 06ER7506A0, 06ER7756A0, 06ER7996A0, 06EM7506A0, 06E25656A0, 06E25656A0,7EM 6E25506A0, 06E25656A0, 06E65656A0, 06E25756A0, 06E65756A0, 06E25996A0, 06E65996A0, 06E35656A0, 06E75656A0, 06E35756A0, 06E75756A0, 06E75756A0,906 ER150600, 06ER165600, 06ER175600, 06ER099600, 06EM150600, 06EA265600, 06EM175600, 06EM199600, 06EA250600602602EF 75600, 06EF275600, 06EA299600, 06EA299600, 06ER750600 06ER765600, 06ER775600, 06ER799600, 06EM750600, 06E2265600, 06E 75600, 06E6275600, 06E2299600, 06E6299600, 06E3265600, 06E7265600, 06E3275600, 06E7275600, 06E7275600, 06E7275600, 06E329090

     

    carlyle compressor

    Bayanin Samfura

    • High-flow, ta atomatik reversible famfo mai yana samar da tabbataccen matsuwa mai lubrication.
    • Tsarin iska mai ɗaukar kaya yana daidaita matsi yayin farawa kuma yana tabbatar da dawowar mai zuwa tarawa.
    • Matsakaicin adadin mai yana riƙe da ƙarin mai a cikin akwati don hana matakan faɗuwa ƙasa da amintaccen kewayon mai yayin fara ambaliya.
    • Pistons ɗin da aka ƙwanƙwasa ƙananan sharewar silinda don haɓaka ƙarfin kwampreso da inganci.
    • Manyan bawuloli masu inganci suna ba da ƙãra ƙwanƙwasa refrigerant da raguwar matsa lamba.
    • Wutar lantarki-matsalar mai.
  • Mai sanyaya kwandon kwandon shara, mai ɗaukar hoto 06DR241BCC06C0/79-66625-00

    Mai sanyaya kwandon kwandon shara, mai ɗaukar hoto 06DR241BCC06C0/79-66625-00

    Ƙarfin doki 6.5 HP

    Kwamfuta Fasaha Maimaita Kwamfuta

    Hanyar sanyaya iska An sanyaya

    Shin Yana šaukuwa Ee

    Gudun Mota 1750 RPM

    Launi mai launin shuɗi

    Sashe na lamba 79-66625-00

    Farashin CFM41

    Amintaccen Man Castrol Icematic

    Nauyi 260 lb. (Bushe)

    Ƙasar Asalin Amurka

    Mai ɗaukar alama

    Jerin CSA Ee

    Cycle/Hertz 50/60 Hz

    Mataki na uku

    No na Silinda 6

    Mai firiji R134A

    Nau'in Semi-Hermetic

    Voltage 400-460 VAC

  • Carlyle compressor 18-10134-23 102-795 18-10134-24 3 Phase Marine refer compressor ZMD26KVE-TFD

    Carlyle compressor 18-10134-23 102-795 18-10134-24 3 Phase Marine refer compressor ZMD26KVE-TFD

    a stock, sabo

    Lambar Samfura:Saukewa: ZMD26KVE-TFD

    Nauyi (Tare da Mai): 42.9 kg (95 lb)

    Man Fetur: Uniqema Emkarate RL-32-3MAF

    Cajin mai: 1774 ml (60 oz)

    Asalin: Amurka

    Muaj Peev Xwm Ntau (BTU): 13500-64800

    Wutar lantarki @ Hz: 380/420 @ 50, 460 @ 60

    Saukewa: R-134A

    Idan wani abu, compressor shine mafi mahimmanci na tsarin sanyaya - kuma wannan gaskiyar ita ce zuciyar ayyukan injiniya da Carrier ke aiwatarwa.Mai ɗaukar hoto yana ƙira da kera wasu mafi kyawun kwampreso don amfani da tsarin sanyaya a kan teku.Duk da haka, yana yiwuwa koyaushe cewa wani ɓangare na compressor ya karya kuma yana buƙatar maye gurbinsa.A Arctic Reefer Service & Repair BV, kuna kan adireshin da ya dace don siyan ɓangarorin maye gurbin daban-daban don kwampreshin mai ɗaukar hoto, kamar gaskets, murfin gasket, bawul ɗin sabis, junctions, har ma da cikakkun kwampressors.Duba gidan yanar gizon mu don samun waɗannan sassa.

     

  • Mai ɗaukar hoto Carlyle Screw Compressor 06NW2209S7NA-A00 Compressor 104W don Chiller
  • 40HP Mai ɗaukar Refrigeration Compressor

    40HP Mai ɗaukar Refrigeration Compressor

    Brand : Mai ɗauka
    Saukewa: 06EA299
    Wutar lantarki: 40 hp
    Silinda: 6
    Yawan aiki (m3/h): 140.40 m3/h
    Cajin mai: 9 l
    Net nauyi: 236 kg
    Saukewa: R22

     

  • Compressor refrigeration injin daskarewa mai ɗaukar firiji 06E 06D jerin farashin

    Compressor refrigeration injin daskarewa mai ɗaukar firiji 06E 06D jerin farashin

    06er099/ 06ea299 Carlyle Compressor, 06ea250 06ea265 Mai ɗaukar Semi-Hermetic Reciprocating Carrier 06e Compressor

    Carlyle 06D/E Semi-hermetic compressors sun dace da firiji na kasuwanci, kwandishan, sanyaya tsari, da ɗakunan muhalli.Suna da sassauƙa sosai kuma ana iya amfani da su tare da yawancin sabbin na'urorin HFC kamar R-507, R-404A, R-407C da R-134a, ban da na'urorin refrigeren na al'ada (R-12, R-22, da R) -502).Ana iya sarrafa compressors a 50 ko 60 hertz kuma an yarda da UL, CE, CSA, da ISO 9002.

  • 120HP Screw Compressor 06NA2300S5NA-A00 Compressor Screw Compressor