Compresseur de défilement 7.5HP JT224D-NYR compresseur de conteneur frigorifique de climatisation
Série Daikin Scroll Compressor JT
Modèle | Sortie (HP) | Source d'alimentation (V/Hz) | Performance | |||
Capacité nominale (W) | Puissance d'entrée (Kw) | COP (W/W) | Bruit (dB) | |||
JT90BCB-Y1L | 3 | 220/50 | 8540 | 2,89 | 2,96 | 58 |
JT90BC-Y1L | 3 | 380/50 | 8540 | 2,75 | 3.11 | 58 |
JT95BCB-Y1L | 3 | 380/50 | 8540 | 2,75 | 3.11 | 58 |
JT95BC-Y1L | 3 | 380/50 | 9030 | 2,89 | 3.12 | 58 |
JT125BC-Y1L | 4 | 380/50 | 11900 | 3.8 | 3.13 | 60 |
380/60 | 14200 | 4.53 | 3.13 | 63 | ||
JT125BCB-Y1L | 4 | 380/50 | 11900 | 3.8 | 3.13 | 60 |
380/60 | 14200 | 4.53 | 3.13 | 63 | ||
JT160BC-Y1L | 5 | 380/50 | 15000 | 4.66 | 3.22 | 60 |
380/60 | 17900 | 5.53 | 3.23 | 63 | ||
JT160BCB-Y1L | 5 | 380/50 | 15000 | 4.66 | 3.22 | 60 |
380/60 | 17900 | 5.53 | 3.23 | 63 | ||
JT212D-Y1L | 7.5 | 380/50 | 21500 | 6.49 | 3.31 | 72 |
JT212D-YE | 400/60 | 25100 | 7,66 | 3.28 | 75 | |
JT236D-Y1L | 7.5 | 380/50 | 24000 | 7.2 | 3.33 | 72 |
JT236D-YE | 400/60 | 28300 | 8.53 | 3.32 | 75 | |
JT265D-Y1L | 8 | 380/50 | 26700 | 7,95 | 3.36 | 72 |
JT265D-YE | 400/60 | 31800 | 9h45 | 3.37 | 75 | |
JT300D-Y1L | 10 | 380/50 | 29900 | 8,85 | 3.38 | 72 |
JT300D-YE | 400/60 | 35200 | 10.4 | 3.38 | 75 | |
JT315D-Y1L | 11 | 380/50 | 31100 | 9h15 | 3.4 | 72 |
JT335D-Y1L | 12 | 380/50 | 34000 | 9,98 | 3.41 | 72 |
JT335D-YE | 400/60 | 40100 | 11.8 | 3.4 | 75 |
Modèle | Puissance (HP) | Tension | Tension d'essai | Capacité | La puissance d'entrée | Actuel | FLIC | Déplacement | |
KW | BTU/H | KW | A | W/W | cm3/tr | ||||
JT212DA-Y1 | 7 | 380-415V,3P,50Hz | 380V/50Hz | 18.9 | 64500 | 6,87 | 11.7 | 2,75 | 117.3 |
JT265DA-Y1 | 8.5 | 23.4 | 79800 | 8.36 | 14.1 | 2.8 | 144,7 | ||
JT300DA-Y1 | 10 | 400V/50Hz | 26,5 | 90400 | 9.44 | 16 | 2,81 | 163 | |
JT335DA-Y1 | 12 | 29,9 | 102000 | 10.7 | 17.9 | 2,79 | 184.2 | ||
JT300DA-Y1L | 10 | 380V/50Hz | 29.6 | 101000 | 9.55 | 16.4 | 3.1 | 163 | |
JT335DA-Y1L | 12 | 33,7 | 115000 | 10.81 | 18.3 | 3.12 | 184.2 | ||
JT212D-P1YE | 7 | 380-415V/400-440V,3P,50/60Hz | 380 V/50 Hz ; 400 V/60 Hz | 21.3/24.9 | 73400/85700 | 6.56/7.74 | 11.3/11.9 | 3.25/3.22 | 117.3 |
JT236D-P1YE | 7.5 | 380V/50Hz | 23,8 | 81900 | 7.27 | 12.4 | 3.27 | 131 | |
400V/60Hz | 28.1 | 96600 | 8.62 | 13.2 | 3.26 | ||||
JT265D-P1YE | 8.5 | 380V/50Hz | 26,5 | 91100 | 8.03 | 13.7 | 3.3 | 144,7 | |
400V/60Hz | 31,5 | 108500 | 9.55 | 14.6 | 3.3 | ||||
JT300D-P1YE | 10 | 380V/50Hz | 29.6 | 102000 | 8,94 | 15.2 | 3.31 | 163 | |
400V/60Hz | 34,9 | 120200 | 10.51 | 16.2 | 3.32 | ||||
JT335D-P1YE | 12 | 380V/50Hz | 33,7 | 116000 | 10.08 | 17.2 | 3.34 | 184.2 | |
400V/60Hz | 39.4 | 136900 | 11.92 | 18.4 | 3.34 |
Daikin, qui a plus de 80 ans d'expérience dans la fabrication de climatiseurs ecntreal, prend une position de leader dans le domaine du CVC
marché.En utilisant la technologie de réfrigération de Daikin, nous avons conçu une technologie de pointe, une originalité, un design parfait et précieux
fabrication en Chine.
Série B Compresseur Daikin non-inverter scroll R22
Série G Daikin compresseur scroll non inverseur R22/R407C/R410A
Série D Compresseur Scroll Daikin R22/R407C
Compresseur scroll à haut rendement Inverter
Écrivez votre message ici et envoyez-le nous