Compressor de desplaçament de 7,5 HP JT224D-NYR compressor de contenidor frigorífic d'aire condicionat
Sèrie Daikin Scroll Compressor JT
Model | Sortida (HP) | Font d'alimentació (V/Hz) | Rendiment | |||
Capacitat nominal (W) | Potència d'entrada (kw) | COP (W/W) | Soroll (dB) | |||
JT90BCB-Y1L | 3 | 220/50 | 8540 | 2,89 | 2,96 | 58 |
JT90BC-Y1L | 3 | 380/50 | 8540 | 2,75 | 3.11 | 58 |
JT95BCB-Y1L | 3 | 380/50 | 8540 | 2,75 | 3.11 | 58 |
JT95BC-Y1L | 3 | 380/50 | 9030 | 2,89 | 3.12 | 58 |
JT125BC-Y1L | 4 | 380/50 | 11900 | 3.8 | 3.13 | 60 |
380/60 | 14200 | 4,53 | 3.13 | 63 | ||
JT125BCB-Y1L | 4 | 380/50 | 11900 | 3.8 | 3.13 | 60 |
380/60 | 14200 | 4,53 | 3.13 | 63 | ||
JT160BC-Y1L | 5 | 380/50 | 15000 | 4,66 | 3.22 | 60 |
380/60 | 17900 | 5,53 | 3.23 | 63 | ||
JT160BCB-Y1L | 5 | 380/50 | 15000 | 4,66 | 3.22 | 60 |
380/60 | 17900 | 5,53 | 3.23 | 63 | ||
JT212D-Y1L | 7.5 | 380/50 | 21500 | 6.49 | 3.31 | 72 |
JT212D-YE | 400/60 | 25100 | 7,66 | 3.28 | 75 | |
JT236D-Y1L | 7.5 | 380/50 | 24000 | 7.2 | 3.33 | 72 |
JT236D-YE | 400/60 | 28300 | 8.53 | 3.32 | 75 | |
JT265D-Y1L | 8 | 380/50 | 26700 | 7,95 | 3.36 | 72 |
JT265D-YE | 400/60 | 31800 | 9.45 | 3.37 | 75 | |
JT300D-Y1L | 10 | 380/50 | 29900 | 8,85 | 3.38 | 72 |
JT300D-YE | 400/60 | 35200 | 10.4 | 3.38 | 75 | |
JT315D-Y1L | 11 | 380/50 | 31100 | 9.15 | 3.4 | 72 |
JT335D-Y1L | 12 | 380/50 | 34000 | 9,98 | 3.41 | 72 |
JT335D-YE | 400/60 | 40100 | 11.8 | 3.4 | 75 |
Model | Potència (HP) | Voltatge | Tensió de prova | Capacitat | Potència d'entrada | Actual | COP | Desplaçament | |
KW | BTU/H | KW | A | W/N | Cm3/r | ||||
JT212DA-Y1 | 7 | 380-415V,3P,50Hz | 380V/50Hz | 18.9 | 64500 | 6,87 | 11.7 | 2,75 | 117.3 |
JT265DA-Y1 | 8.5 | 23.4 | 79800 | 8.36 | 14.1 | 2.8 | 144,7 | ||
JT300DA-Y1 | 10 | 400V/50Hz | 26.5 | 90400 | 9.44 | 16 | 2,81 | 163 | |
JT335DA-Y1 | 12 | 29.9 | 102000 | 10.7 | 17.9 | 2,79 | 184.2 | ||
JT300DA-Y1L | 10 | 380V/50Hz | 29.6 | 101000 | 9.55 | 16.4 | 3.1 | 163 | |
JT335DA-Y1L | 12 | 33.7 | 115000 | 10.81 | 18.3 | 3.12 | 184.2 | ||
JT212D-P1YE | 7 | 380-415V/400-440V,3P,50/60Hz | 380V/50Hz;400V/60Hz | 21.3/24.9 | 73400/85700 | 6,56/7,74 | 11.3/11.9 | 3.25/3.22 | 117.3 |
JT236D-P1YE | 7.5 | 380V/50Hz | 23.8 | 81900 | 7.27 | 12.4 | 3.27 | 131 | |
400V/60Hz | 28.1 | 96600 | 8,62 | 13.2 | 3.26 | ||||
JT265D-P1YE | 8.5 | 380V/50Hz | 26.5 | 91100 | 8.03 | 13.7 | 3.3 | 144,7 | |
400V/60Hz | 31.5 | 108500 | 9.55 | 14.6 | 3.3 | ||||
JT300D-P1YE | 10 | 380V/50Hz | 29.6 | 102000 | 8,94 | 15.2 | 3.31 | 163 | |
400V/60Hz | 34.9 | 120200 | 10.51 | 16.2 | 3.32 | ||||
JT335D-P1YE | 12 | 380V/50Hz | 33.7 | 116000 | 10.08 | 17.2 | 3.34 | 184.2 | |
400V/60Hz | 39.4 | 136900 | 11.92 | 18.4 | 3.34 |
Daikin, que té més de 80 anys d'experiència en la fabricació d'aire condicionat real, ocupa una posició de lideratge en HVAC
mercat.Utilitzant la tecnologia de refrigeració de Daikin, hem creat tecnologia avançada, originalitat, disseny perfecte i preuat
fabricació a la Xina.
Compressor de desplaçament sense inversor de la sèrie B Daikin R22
Compressor de desplaçament sense inversor de la sèrie G Daikin R22/R407C/R410A
Compressor Scroll Daikin de la sèrie D R22/R407C
Compressor scroll inverter d'alta eficiència
Escriu el teu missatge aquí i envia'ns-ho