R404a Danfoss Maneurop Piston Refrigeration Compressor MTZ125–4VI , MTZ160HW4VE, MTZ100, MTZ64, MTZ144HV4VE

Nkọwa dị mkpirikpi:

Ụdị Compressor: MTZ125
friji: R404A
Igwe nju oyi 50Hz, EN12900
Ike oyi Btu/h: 53600
Ntinye ike kW: 8.44
Ntinye ugbu a: 13.79
EER Bth/Wh: 6.35


Nkọwa ngwaahịa

Mkpado ngwaahịa

1.R404a Danfoss Maneurop Piston Refrigeration Compressor MTZ125--4VM

50 Hz ogo ARI

Ike oyi Btu/h: 57500

Ntinye ike kW: 9.22

Ntinye ugbu a A: 14.87

EER Bth/Wh: 6.23

60 Hz ogo ARI

Ike oyi Btu/h: 68300

Ntinye ike kW: 11.37

Ntinye ugbu a: 15.41

EER Bth/Wh: 6.00

2.Cold ụlọ 10hp Maneurop Reciprocating Compressor Model MTZ125

Ụdị Maneurop
Nlereanya MTZ125HU4VE
Ike jụrụ oyi (kw) 57.5
ike inyinya (hp) 10
Ntugharị ) (m3/h) 37.49
Igwe nju oyi R404a R407c R134a
Ụdị na-emeghachi omume
ugbu a (A) 13.79
Ibu (kg) 64
COP(W/W) 2.85

Compressor nomenclature

MTZ125 (2)
Koodu No. HP MT-R22 MTZ-R407C MTZ-R134a MTZ-R404
Kw BTUH EER Kw BTUH EER Kw BTUH EER Kw BTUH EER
MT/MTZ18 1.5 1.74 15900 9.15 1.67 15300 9.13 1.22 11200 9.2 1.76 10300 5.1
MT/MTZ22 2 2.27 22000 9.68 2.17 19600 9 1.54 14800 9.63 2.05 14100 6.01
MT/MTZ28 2.5 3.07 30200 9.86 2.83 25100 8.9 2.04 19300 9.42 2.68 18300 5.96
MT/MTZ32 2.75 3.58 33000 9.22 3.21 28400 8.86 2.39 20900 8.76 2.99 20100 5.85
MT/MTZ36 3 4.05 38000 9.38 3.75 32700 8.73 2.75 24500 8.91 3.34 23200 6.05
MT/MTZ40 3.5 4.63 42900 9.27 4.33 37400 8.64 3.08 27900 9.03 3.77 26400 6.11
MT/MTZ44 4 4.67 45200 9.69 4.37 43000 9.84 3.14 29800 9.51 4.18 27800 6.65
MT/MTZ50 4.5 5.18 50500 9.74 4.96 48100 9.71 3.6 34500 9.57 4.83 32500 6.73
MT/MTZ56 5 6.05 56400 9.32 5.67 54300 9.59 3.95 38000 9.62 5.44 36500 6.71
MT/MTZ64 5.5 6.8 64800 9.53 6.36 60400 9.5 4.68 45300 9.66 6.12 41500 6.78
MT/MTZ72 6 7.58 70100 9.26 7.22 67900 9.41 5.19 50000 9.63 6.91 46500 6.72
MT/MTZ80 7 8.56 80000 9.35 8.24 76900 9.33 6 56500 9.42 8.03 52500 6.54
MT/MTZ100 9 9.59 95900 10 9.9 94400 9.53 6.5 63900 9.84 8.72 60800 6.07
MT/MTZ125 10 12.81 124600 9.73 12.62 122100 9.67 7.72 78900 10.22 11.37 78400 6
MT/MTZ144 12 14.36 140700 9.8 14.47 137200 9.48 9.82 96900 9,87 13 92300 6.19
MT/MTZ160 13.5 16.09 156800 9,75 16.67 155100 9.31 10.92 107600   13.3    

 

Ngwa

Danfoss Maneurop compressors na-emegharị ihe bụ nke ahaziri maka ngwa nwere ọnọdụ ọrụ dị iche iche.All components bụ nke elu àgwà na nkenke iji mesie a ogologo ngwaahịa life.The compressor imewe na-enye ohere maka moto na-100% mmiri-gas mma.Uru dị mma nke nchebe moto nke ime ime, nhazi valve okirikiri dị elu na-arụ ọrụ dị elu na moto torque dị elu na-enye maka ntinye dị mma.

https://www.hyrefrigeration.com/about-us/

Uru

Ihe ndakọrịta refrigerant R-134a, R-407C Usoro 3 arụrụ arụ enyere na ọnọdụ-7°C evap.temp;35°C ikuku.temp;5K mmiri ara ehi;4K subcooling maka R-407C na 50 Hz Heating Capacity4.90 kWVoltages380-420 V na 50 Hz, 460 V na 60 HzFrequency50, 60 HzPower Ntinye 1.13 kWCOP3.38Displacement³/h20m2 xverm2m5mVrm2mVrmVerm2mverm3. 364 mm ( W x L x H) / 23 kgPED Category1Low/Elu Akụkụ PS22.6/32 mmanya(g) Kachasị arụ ọrụ ugbu a4.1 ALocked Rotor Current26 ASound Power71 dBA

FAQ

Q: Gịnị bụ MOQ?

A: Nọmalị 1 ibe.

Q: Kedu maka àgwà compressor?

A: Ogo ama ama.

Q: Kedu ihe voltaji compressor ị nwere ike ịnye, ma ọ bụrụ na anyị nwere ike ịnwe voltaji pụrụ iche?

A: Fọrọ nke nta ka ụdị voltaji niile anyị niile nwere ike ịnye.

Ajụjụ: Kedu oge ịkwụ ụgwọ?

A: Nọmalị T / T ma ọ bụ azụmahịa mmesi obi ike anyị nwere ike na-anabata .

Ajụjụ: Mgbe ị na-ebupu ihe m?

A: N'ezie, ụbọchị 3-7 mgbe ị nwetasịrị ụgwọ gị, mana enwere ike ịmekọrịta ya dabere na usoro qty na usoro mmepụta.

Ajụjụ: Kedu maka akwụkwọ ikike?

A: All compressor anyị nwere otu afọ akwụkwọ ikike.

Ajụjụ: Enwere m ike ịtụkwasị gị obi?

A: Ee n'ezie.Anyị bụ "alibaba" onye na-ebubata ngwaahịa.

Ajụjụ: ị nwere ike izipu sample?

A: ee, mana pls kwụọ ụgwọ nlele na ibu.

Ajụjụ: Gịnị bụ isi ngwaahịa gị?

A: Anyị na-elekwasị anya: Semi-Hermetic Compressor, Hermetic Compressor, Refrigeration Compressor unit.


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a ziga anyị ya