R404a Danfoss Maneurop Piston Refrigeration Compressor MTZ125–4VI , MTZ160HW4VE,MTZ100,MTZ64,MTZ144HV4VE

Kufotokozera Kwachidule:

Compressor Model: MTZ125
Firiji: R404A
Firiji 50Hz, EN12900 mavoti
Kuzizira Mphamvu Btu/h: 53600
Kulowetsa Mphamvu kW: 8.44
Zolemba Pano A: 13.79
EER Bth/Wh: 6.35


Tsatanetsatane wa Zamalonda

Zogulitsa Tags

1.R404a Danfoss Maneurop Piston Refrigeration Compressor MTZ125--4VM

50 Hz ARI mlingo

Kuzizira Mphamvu Btu/h: 57500

Kulowetsa Mphamvu kW: 9.22

Zolowetsa Panopa A: 14.87

EER Bth/Wh: 6.23

60 Hz ARI mlingo

Kuzizira Mphamvu Btu/h: 68300

Kulowetsa Mphamvu kW: 11.37

Zolowetsa Panopa A: 15.41

EER Bth/Wh: 6.00

2.Cold room 10hp Maneurop Reciprocating Compressor Model MTZ125

Mtundu Maneurop
Chitsanzo Chithunzi cha MTZ125HU4VE
Kuzirala (kw) 57.5
Mphamvu ya akavalo (hp) 10
Kusamuka ) (m3/h) 37.49
Refrigerant R404a R407c R134a
Mtundu kubwezerana
panopa (A) 13.79
Kulemera (kg) 64
COP (W/W) 2.85

Compressor nomenclature

MTZ125 (2)
Kodi No. HP Mtengo wa MT-R22 MTZ-R407C MTZ-R134a MTZ-R404
Kw BTUH EER Kw BTUH EER Kw BTUH EER Kw BTUH EER
MT/MTZ18 1.5 1.74 15900 9.15 1.67 15300 9.13 1.22 11200 9.2 1.76 10300 5.1
MT/MTZ22 2 2.27 22000 9.68 2.17 19600 9 1.54 14800 9.63 2.05 14100 6.01
MT/MTZ28 2.5 3.07 30200 9.86 2.83 25100 8.9 2.04 19300 9.42 2.68 18300 5.96
MT/MTZ32 2.75 3.58 33000 9.22 3.21 28400 8.86 2.39 20900 8.76 2.99 20100 5.85
MT/MTZ36 3 4.05 38000 9.38 3.75 32700 8.73 2.75 24500 8.91 3.34 23200 6.05
MT/MTZ40 3.5 4.63 42900 9.27 4.33 37400 8.64 3.08 27900 9.03 3.77 26400 6.11
MT/MTZ44 4 4.67 45200 9.69 4.37 43000 9.84 3.14 29800 9.51 4.18 27800 6.65
MT/MTZ50 4.5 5.18 50500 9.74 4.96 48100 9.71 3.6 34500 9.57 4.83 32500 6.73
MT/MTZ56 5 6.05 56400 9.32 5.67 54300 9.59 3.95 38000 9.62 5.44 36500 6.71
MT/MTZ64 5.5 6.8 64800 9.53 6.36 60400 9.5 4.68 45300 9.66 6.12 41500 6.78
MT/MTZ72 6 7.58 70100 9.26 7.22 67900 9.41 5.19 50000 9.63 6.91 46500 6.72
MT/MTZ80 7 8.56 80000 9.35 8.24 76900 9.33 6 56500 9.42 8.03 52500 6.54
MT/MTZ100 9 9.59 95900 10 9.9 94400 9.53 6.5 63900 9.84 8.72 60800 6.07
MT/MTZ125 10 12.81 124600 9.73 12.62 122100 9.67 7.72 78900 10.22 11.37 78400 6
MT/MTZ144 12 14.36 140700 9.8 14.47 137200 9.48 9.82 96900 9.87 13 92300 6.19
MT/MTZ160 13.5 16.09 156800 9.75 16.67 Mtengo wa 155100 9.31 10.92 107600   13.3    

 

Kugwiritsa ntchito

Danfoss Maneurop reciprocating compressor amapangidwa mwapadera kuti azigwiritsidwa ntchito ndi mitundu yosiyanasiyana yogwiritsira ntchito.Zigawo zonse ndi zapamwamba kwambiri komanso zolondola kwambiri kuti zitsimikizire kuti moyo wautali wa chinthucho udzakhalapo.Mapangidwe a kompresa amalola kuti mota ikhale 100% yoziziritsa gasi.Ubwino wodzitchinjiriza wamkati wamagalimoto, kapangidwe kabwino ka ma valve ozungulira komanso ma torque okwera amapereka kuyika kwabwino.

https://www.hyrefrigeration.com/about-us/

Ubwino

Refrigerants compatiblesR-134a, R-407C Phase3Magwiridwe operekedwa pamikhalidwe-7 °C evapop.temp;35 ° C kutentha.temp;5 K kuyamwa kwakukulu;4 K subcooling ya R-407C pa 50 HzHeating Capacity4.90 kWVoltages380-420 V pa 50 Hz, 460 V pa 60 HzFrequency50, 60 HzPower Input1.13 kWCOP3.38Displacement4. 364 mm ( W x L x H) / 23 kgPED Gulu1Low/High Side PS22.6/32 bala(g)Njira Yochulukira Pakalipano4.1 Rotor Yotsekedwa Pakalipano26 ASound Power71 dBA

FAQ

Q: Kodi MOQ ndi chiyani?

A: Nthawi zambiri chidutswa chimodzi.

Q: Nanga bwanji compressor quality?

A: Khalidwe lodziwika bwino.

Q:Ndi ma voltages ati a kompresa omwe mungapereke, ngati titha kukhala ndi ma voltages apadera?

A: Pafupifupi mitundu yonse yamagetsi yomwe tonse titha kupereka.

Q: Nthawi yolipira yanji?

A: Nthawi zambiri T/T kapena Trade chitsimikizo tingavomereze.

Q: Mukatumiza oda yanga?

A: Nthawi zambiri 3-7 masiku mutalandira malipiro anu, koma akhoza kukambitsirana potengera dongosolo qty ndi ndondomeko kupanga.

Q: Nanga bwanji chitsimikizo?

A: Compressor yonse tili ndi chitsimikizo cha chaka chimodzi.

Q: ndingakukhulupirireni?

A: Inde ndithu.Ndife "alibaba" ogulitsa otsimikizika.

Q: mungatumize zitsanzo?

A: inde, koma pls kulipira chitsanzo mtengo ndi katundu.

Q: Kodi zinthu zanu zazikulu ndi ziti?

A: Timayang'ana kwambiri: Semi-Hermetic kompresa, Hermetic kompresa, Refrigeration kompresa unit.


  • Zam'mbuyo:
  • Ena:

  • Lembani uthenga wanu apa ndikutumiza kwa ife