I-Copeland Refrigeration scroll compressor ZP235KCE-TWD-450 380-420V 3-Phase R410A

Inkcazelo emfutshane:

Ukusebenza

I-Evaporator Temp.(ºF) 45 45

Ukunciphisa iTemp.(ºF) 130 100

Buyisela iGas Temp.(ºF) 65 65

Ulwelo lweTemp.(ºF) 115 85

Umthamo (Btu/hr) 235000 290000

Amandla (W): 21100 15400

EER (Btu/Wh): 11.10 18.80

UkuHamba koMninzi (Ibs/hr): 3460 3590

Okwangoku (Amps): 30.60 23.60


Iinkcukacha zeMveliso

Iithegi zeMveliso

Imodeli: ZP235KCE-TWD-551, Copeland ZP235KCE-TWD-965 Skrola iCompressor 20 HP 235000 BTUH 575/60/3 R410A Rotalock ZP235KCE-TWE-265, ZP232KCE65PTZ2KTWD-TWD-TWD-TWD-TWD-TWD6-TWD-TWD-TWD-265, ZP232KCE66KCE-TWD6 I-KCE-TEE-266HFC , R-410A, 60 Hz, 3-isigaba, 460 V

Into yokufaka umoya endlini

Iimpawu zeCopeland Compressor

1. Uluhlu olubanzi lokuskrola
2. Izinga lokujikeleza kweoli ephantsi
3. Isandi esisezantsi kunye nenqanaba lokungcangcazela
4. Ukusebenza okuphezulu kokugcina ukusetyenziswa kwamandla
5. Indawo yeMvelaphi: eTshayina (eMainland)
6. Isibandisi: R22/R410A/R407C/R134a/R404A/R507

Iicompressor zesantya eziguquguqukayo zeCopeland Scroll zimele incopho yokuthembeka ngophuculo olunje:

• Iialgorithms zokhuseleko olusebenzayo: ezibonelelwa yi-Emerson™ motor control drive
• Uyilo oluqinileyo lokuskrola: Ukuthembeka okugqwesileyo kukhuphiswano lwetekhnoloji yoxinzelelo
• Ubungqina bokusebenza ebaleni: iminyaka engama-25 yamava okuskrola kunye nofakelo olungaphezulu kwezigidi ezili-100 kwihlabathi liphela.

Umzekelo I-ZP235KCE-TWD-551
Isakhono seMveliso 1000 Iqhekeza/Amaqhekeza ngenyanga
Indawo yoqobo eMelika
Unyaka 2020
Isiqinisekiso VDE, TUV kunye neCE
I-Voltage 380
Isigaba 3
Ukufuduswa 37.97
Amandla eHashe 20HP
Umthamo wokupholisa(w) 5700
Igalelo lamandla(w) 172733
Cop(w/w) 3
Yangoku(A) 29.9
Ubunzima 140

 

 

Copeland ZP Series – Skrola Compressors ngeR410a.

« Ifanelekile kwiiNkqubo zeChiller ezipholileyo zoMoya ukuya kuthi ga kwi-900kw (1100kw Ukuba Amanzi Apholile).
« Ukuguquguquka okungenakulinganiswa, ukuSebenza kunye nokuthembeka okuqinisekisiweyo.
« Ufanelekile kwi-Tandem, ulungelelwaniso lwe-Trio (ngoku alulinganiyo ngoku), ukubonelela ngokuSebenza okuPhezulu kweXesha.
« Imvulophu yokusebenza eyandisiweyo ye-5k ifanelekile kwizicelo zeMpompo yobushushu.
« I-TEWI ephantsi (I-Total Equivalent Impact yokufudumala).
« Isandi esisezantsi kunye namanqanaba okungcangcazela.
« Amazinga aphantsi okujikeleza kweoli.
« I-Sound Shell okanye i-Blanket ibonelela nge-10dBA eyongezelelweyo (iKit egcweleyo) yokuthomalalisa isandi sokusebenza okuthe cwaka (Ngokuzithandela)

 

Copeland Skrola Air Conditioning Compressors

  • Iimodeli ze-R-410A kunye ne-R-407C/R-134A
  • I-Copeland-qualified tandem kunye ne-trio indibaniselwano (enokulingana kunye nokungalingani) ukuya kwi-45 HP kwisekethe nganye yokusebenza kakuhle kwexesha lokupholisa (ESEER) kunye nokufudumeza (SCOP)
  • Yenzelwe ukusebenza kakuhle kwe-R-410A kunye nokusebenza
  • Iimpawu zoKhuseleko oluPhezulu loBubushushu bokuSkrola (ASTP) ukugada icompressor ngokuchasene nobushushu obugqithisiweyo
  • Ukukhanya, uyilo olubambeneyo olunezifakelo zokufunxa ezincinci zokonga iindleko

  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi