Nā huahana

  • ʻO ka mea hoʻoheheʻe ea Hitachi screw compressor 60ASCP-Z, Hitachi Ac Compressor, Hitachi Refrigerator Compressor 60hp

    ʻO ka mea hoʻoheheʻe ea Hitachi screw compressor 60ASCP-Z, Hitachi Ac Compressor, Hitachi Refrigerator Compressor 60hp

    Hoʻohana ʻo Hitachi screw chillers i ka Hitachi twin screw compressor hou loa e hoʻomaikaʻi i ke ʻano o ka mea hoʻololi wela, hoʻomaikaʻi piha i ka hana a me ka pono.
    Hiki ke hāʻawi i kahi ʻano nui o nā huahana noi:
    Hoʻomaʻalili ʻia ka wai: haʻahaʻa haʻahaʻa haʻahaʻa ʻelua kūlana hana
    (Hiki i ka wela liʻiliʻi ke hiki i - 20 ℃)
    ʻO nā kumu hoʻōla wela, nā ʻāpana wai puna wela, etc
    Hoʻoluʻu ʻia ka ea: nā hiʻohiʻona hana a puni ka makahiki, nā ʻāpana wai wela
    ʻĀpana mālie loa (leo haʻahaʻa loa o ka ʻoihana
    Horizontal), etc
    ʻO ka nui o ka mana o ka refrigeration: ma luna o 45kW

    Hoʻohālikelike ʻia me nā ʻano compressors ʻē aʻe, ʻo Hitachi screw compressors maʻamau ka loaʻa ʻana o nā pōmaikaʻi aʻe, a hoʻohana nui ʻia i ka ea ea, refrigeration, mea kanu, hoʻomehana ea, a me nā mea ʻē aʻe.
    ① He liʻiliʻi nā ʻāpana hoʻoheheʻe o ka mea hoʻoheheʻe, a ʻaʻohe ʻāpana e like me nā valve hana pono e hoʻololi ʻia i kahi manawa pōkole.No laila, he hilinaʻi kiʻekiʻe, a ʻaʻohe pono no ka hoʻoponopono lōʻihi He maʻalahi ke ʻano, a ʻo ka helu o nā ʻāpana nui e pili ana i ka 1/10 o ke ʻano o ke ʻano pānaʻi (hoʻohālikelike ʻia me kā mākou hui) E hoʻopaʻa i kahi hoʻonohonoho hoʻopaʻa paʻa pālua, haʻahaʻa. walaʻau.
    ④ He haʻahaʻa haʻahaʻa ka compression refrigerant no ka mea ua hoʻopaʻa ʻia ma o ka hoʻomau mau ʻana.
    ⑤ ʻO ka maikaʻi kiʻekiʻe, ʻoi loa i nā noi haʻahaʻa haʻahaʻa, ka hoʻoluʻu ʻana o ka ea wela a me ka hoʻomehana ʻana, hiki ke pāʻani i kahi hana koʻikoʻi.⑥ ʻElua mau ʻano o ka hoʻomalu ʻana i ka mana: phased a hoʻomau, hiki ke hoʻololi ākea i nā pono like ʻole.
    ⑦ Inā hoʻokomo ʻia ka mea hoʻoheheʻe wai ma ka ʻaoʻao hoʻoheheʻe o ka compressor, ʻaʻole e piʻi ka mahana o ke kinoea i hoʻokuʻu ʻia ma luna o 120 ℃.⑧ E hoʻohana i ka aila lubricating synthetic kūikawā i loaʻa ka mahana hoʻokuʻu o 120 ° C a ʻaʻole carbonize a deteriorate@ He liʻiliʻi ka ukana hoʻomaka o ka compressor.Hiki ke hoʻomaka ke kaʻa me ka hoʻohana ʻana i kahi ʻano delta hoʻomaka liʻiliʻi( λ—— △)。

    60ASCP-Z hitachi compressor kiko'ī

    ʻO ka pahu hau: r22/R407
    Lio mana(hp):60
    Ka uila: 380~415V/ 3PH/50hz
    220/240v-50hz
    hiki ke hooluolu (KW): 184.9
    Hoʻoneʻe (m3/h): 208.7
    aila uku: 6L
    kaʻa: 45kw 2p
    paona upena: 460kg
  • Copeland Digital Scroll Compressor ZPD72KCE-TFD-433 kuai

    Copeland Digital Scroll Compressor ZPD72KCE-TFD-433 kuai

    Hoʻohālike:ZPD72KCE-TFD-433
    Mea hoʻoheheʻe: R-410a
    Voltage: 380-420V, 50 Hz, 3Ph
    Hiki ke hoʻoluʻu: 5700w
    EER:10.3
    KEIKI:19.71 in
    kala: ʻeleʻele
    Kaumaha ʻupena:88 kg
  • 10HP Reciprocating compressor MTZ125HU4VE

    10HP Reciprocating compressor MTZ125HU4VE

    LRA 105 A
    MCC 27 A
    Helu kumu hoʻohālike MTZ125HU4VE
    Pale kaʻa Paʻa hoʻopaʻa kaumaha kūloko
    ʻO ke kukui kau ʻana [Nm] 50 Nm
    ʻO ka mana hoʻoluʻu nominal ma 50Hz 15.7 kW
    ʻO ka mana hoʻoluʻu nominal ma 60Hz 20 kW
    Ka helu o ka hoʻomaka ʻana i kēlā me kēia hola [Max] 12
    Kaʻaila ʻaila [L] 3.9 L
    ʻAila kaulike 3/8” ke ahi SAE
    ʻAila hoʻohālikelike torque [Nm] 30 Nm
    Kuhi ʻaila 175PZ
    ʻO ke kiʻekiʻe o ka ʻeke [mm] 720 mm
    ʻO ka lōʻihi o ka ʻeke [mm] 570 mm
    Ke kaumaha o ka ʻeke [Kg] 71 kg
    Laulā o ka pūʻolo [mm] 400 mm
    Hōʻuluʻulu paʻi pūʻolo hoʻokahi
    Ka nui paʻi 1
    Māhele 3
    Nā pilina mana Nā mea hoʻohui wili 10-32 UNF x 9.5
  • 20HP Copeland scorll compressor ZP235KCE-TWD-522 Compressor

    20HP Copeland scorll compressor ZP235KCE-TWD-522 Compressor

    Copeland ZP235KCE-TWD-522 Compressor

    Hiki i ka Copeland ZP235KCE-TWC-522 ke hoʻohana i ke kinoea refrigerant R410A.

    ʻO 380 ~ 420v kona kaha uila.

    He compressor scroll ekolu ia me ka mana hooluolu 44000W.

    Hele mai ia me mākou 20 Horsepower range, a me 13333 W mana hoʻokomo.

  • Copeland ZP485KCE-TWD-966 Paʻi Paʻi Paʻi 485000 BTUH 460/60/3 R410A

    Copeland ZP485KCE-TWD-966 Paʻi Paʻi Paʻi 485000 BTUH 460/60/3 R410A

    NĀ KULA: ZP485KCE-TWD-522
    Mana Lio: 40HP
    Voltage:380-420V/3/50Hz,460V/3/60Hz
    Kaha: 105KW

  • Bitzer Reciprocating Air Conditioner Compressor 6f-50.2-40p

    Bitzer Reciprocating Air Conditioner Compressor 6f-50.2-40p

    ʻAno:6F-50.2Y-40P (4x)
    Helu waiwai:M22-1330
    Hiki ke hoʻoluʻu:242 kW
    Noi:Hoʻoluʻu
    Ka neʻe ʻana:4x 151,6 m³/h
    Mea hoʻoheheʻe:HFC
    Ana:3250 x 1720 x 1350 mm
    Kaumaha:1,250 kg
    Makahiki:2006
    Helu ma ka waihona:1 ʻāpana
    wehewehe:ʻO kahi ʻāpana hoʻoemi Bitzer maikaʻi me 4 piston compressors a me kahi pā uila.ʻO ka mana i haʻi ʻia ma kahi mahana evaporating o -5°C a me kahi mahana condensing o +40°C i ka wā e hoʻohana ai iā R134a (I ka hoʻohana ʻana iā R404A: Q= 383.2 kW ma Tv= -5°C a me Tc= +40°C).

  • ʻO ka mea hoʻoheheʻe hau 4PCS-10.2-40P no ka lumi ʻoluʻolu

    ʻO ka mea hoʻoheheʻe hau 4PCS-10.2-40P no ka lumi ʻoluʻolu

    • ʻO ka pahu hau:R22/R404a /R134a/R507a
    • Voltage: 3P 380v~460V, 50/60HZ; Hoʻokahi māhele 220V, 50HZ/60HZ
    • Hoʻopilikino i ka uila: 3Phase, 220V/50/60Hz
    • ʻAno: 4PCS-10.2-40P 10HP COMPRESSOR REFRIGERATION
  • Bitzer Semi-hermetic Reciprocating Compressor 4GE-30Y-40P

    Bitzer Semi-hermetic Reciprocating Compressor 4GE-30Y-40P

    Nā kikoʻī

    ʻAʻole. 14619
    Brand Bitzer
    ʻAno 4GE-30Y-40P
    Pahu hau Freon
    kW ma 0ºC/+40ºC 70,6
    kW ma -5ºC/+40ºC 58,6
    kW ma -10ºC/+40ºC 48,2
    kW ma -20ºC/+40ºC 31,4
    kW ma -30ºC/+40ºC 19,2
    kW ma -40ºC/+40ºC 10,5
    kW ma -45ºC/+40ºC 7,2
  • 13HP Paʻi kaomi SZ161T4VC SZ161-4VAI

    13HP Paʻi kaomi SZ161T4VC SZ161-4VAI

    Hoʻohālike: SZ161T4VC

    ʻO ka mana hoʻoluʻu nominal ma 50Hz 33.9 kW
    ʻO ka mana hoʻoluʻu nominal ma 60Hz 46 kW
    ʻO ka mana hoʻomehana nominal ma 50Hz 32.3 kW
    Ka helu o ka hoʻomaka ʻana i kēlā me kēia hola [Max] 12
    Kaʻaila ʻaila [L] 3.6 L
    ʻAila kaulike 3/8” ke ahi SAE
    ʻAila hoʻohālikelike torque [Nm] 48 Nm
    Kuhi ʻaila 160SZ
    ʻAno ʻaila POE
  • 15HP Copeland Haʻahaʻa Mahana Rerigeration compressor ZF48K4E-TWD-551

    15HP Copeland Haʻahaʻa Mahana Rerigeration compressor ZF48K4E-TWD-551

    ZF48K4E-TWD-551

    Mechanical

    Displ(i^3/Rev): 15.00

    Displ(ft^3/h): 1822.43

    Ka lōʻihi (ma): 12.63

    Laulā holoʻokoʻa (ma): 14.06

    Kiʻekiʻe holoʻokoʻa (i loko o): 23.36

    Ka Loihi Kauʻana (i loko o): 8.65

    Kaulana Laulā (ma): 8.65

    Kiʻekiʻe Kauʻana (i loko): 23.53*

    Ka nui o ka mimi (i) ʻAno: 2 1/4 Rotalock

    Hoʻokuʻu ʻia (Ma) ʻAno: 1 3/4 Rotalock

    Uku aila mua (oz): 140

    ʻO ka ʻaila hou (oz): 137

    Kaumaha Uuna (ibs): 235.0

    Ka Leo Kūʻokoʻa Kūloko (i^3): 1120.0

    Mana Lio: 15.00

  • 7HP Reciprocating Compressor, 3-Phase, 3500 RPM, 60 Hz, R-404A (460V) MTZ80HP4AVE (MTZ80-4VI)
  • 25HP mea lawe Semi-Hermetic Compressor (50/60Hz) 06E2565600

    25HP mea lawe Semi-Hermetic Compressor (50/60Hz) 06E2565600

    Mea lawe 06E2565600 Carlyle Compressor 25HP

    Pani: 06E2565600

    Kaumaha 566 Paona (paona)
    Laulā 26 ʻīniha (Ma)
    Kiʻekiʻe 26.5 Iniha (I)
    ʻĀina i hoʻokumu ʻia ʻo USA
    Mea Pilikino No
    Pono ka palapala EPA No
    Loihi 34 ʻīniha (I)
    Hoʻohana ʻana i ka ea
    Brand Carlyle
    CFM 65
    Kaapuni/Hertz 50,60
    ISO Code US
    Hoʻopaʻa Rotor Amps 446
    Māhele ʻEkolu
    R-22
    ʻAno Semi- Hermetic
    Voltage 400/460 VAC

    E kauoha e like me ia, ʻaʻole hiki ke hoʻihoʻi ʻia, ʻaʻole hiki ke hoʻopau i ke kauoha.

    ʻO nā kiʻi no ka hoʻohālike, nā huahana i pili i ka hoʻoponopono hou ʻana o ka mea hana